Bradford-White Corp TGHE-160I-N(X), TGHE-1991-N(X) Section II Specifications, Model

Page 6

SECTION II: SPECIFICATIONS

Table 1. Specifications.

 

Model

 

TGHE-160I-N(X)

 

TGHE-199I-N(X)

 

Minimum Rate Btu/h

 

 

 

9,500 (Natural)

/ 10,300 (Propane)

 

 

Maximum Rate Btu/h

 

 

157,000

 

199,000

 

 

Flow Rate (Min-Max) *

 

 

 

0.4-8.0 GPM (1.5-30 L/min)

 

0.4-9.8 GPM (1.5-37 L/min)

 

Flow Rate (45°F rise)

 

 

 

6.6 GPM (25 L/min)

 

8.5 GPM (32 L/min)

 

Default Temperature Setting

 

 

104°F (40°C)

 

 

Maximum Temp Setting

 

185°F (85°C)

 

(commercial **)

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Temp Setting (residential)

 

 

Selectable at 120°F (49°C) or 140°F (60°C)

 

 

Minimum Temperature Setting

 

98°F (37°C)

 

Weight

 

 

 

64 lb (29 kg)

 

71 lb (32.2 kg)

 

Energy Factor

 

 

0.96

 

0.94

 

 

Thermal Efficiency

 

 

 

 

95%

 

 

Noise level (inside rating)

 

50 dB

 

Electrical

 

 

 

Normal

 

 

63 W

 

80 W

 

 

 

 

Standby

 

 

2 W

 

Consumption

 

 

 

 

 

 

 

 

 

Anti-frost Protection

 

 

220 W

 

220 W

 

By-Pass Control

 

 

 

Electronic

 

Minimum Gas

 

 

Natural Gas

 

 

5.0 inch W.C.

 

 

Supply

 

 

Propane

 

8.0 inch W.C.

 

Pressure

 

 

 

Maximum Gas

 

 

Natural Gas

 

 

10.5 inch W.C.

 

 

Supply

 

 

Propane

 

13.5 inch W.C.

 

Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of Appliance

 

 

 

Condensing, Tankless, Direct Vent, Temperature controlled continuous flow gas

 

 

 

 

 

water heater

 

 

 

 

 

 

 

 

 

 

 

Operation

 

 

 

With or without remote controls, mounted in kitchen, bathroom, etc.

 

 

 

 

 

 

 

 

 

 

 

Approved Gas Type

 

 

 

Natural Gas or Propane - ensure unit matches gas type supplied at the installation

 

 

 

 

location.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4"

 

Connections

 

 

 

 

 

 

 

MNPT

 

 

 

 

 

 

 

 

 

Ignition System

 

 

 

Direct Spark Ignition

 

 

Electric Connections

 

 

 

Water Heater: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)

 

Water Temperature Control

 

 

Simulation Feedforward and Feedback

 

 

Minimum Water Supply Pressure

 

50 PSI (Recommended 60-80 PSI for maximum performance)

 

Maximum Water Supply Pressure

 

 

150 PSI

 

 

Remote Control Cable

 

 

 

Non-Polarized Two Core Cable (Minimum 22 AWG)

 

ENERGY STAR® Qualified

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

*Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.

**For commercial and hydronic applications requiring higher temperatures. Requires the use of an optional controller (P/N 239-48789-00).

Bradford White Corporation is continually updating and improving products. Therefore, specifications are subject to change without prior notice.

The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the purpose of input adjustment.

6

Image 6
Contents TGHE-160I-NX & TGHE-199I-NX Table of Contents Page Page If YOU Smell GAS Section II Specifications ModelDimensions Pressure Drop psi Water Flow Rate gpm Section III Installation Instructions Unpacking Water Heater LocationRemove Carton Mount Water Heater on the Wall State Regulations Important In the State of Massachusetts 248CMR 4.00Section IV Water Connections Water QualityInstructions for Connections Page Approximate TIME/TEMPERATURE Relationships in Scalds Recommended Piping for a Basic Installation Recommended Piping for a Circulation Systems Recommended Piping for Power Failure Freeze Protection Recommended Piping for Freeze ProtectionPressure Relief Valve Page Page Section V Venting Venting Vent / Air Intake Terminal Locations Direct Vent Terminal LocationVenting System Installation Venting System LayoutPrior to the Installation of the EverHot Direct Vent System Horizontal Direct Vent InstallationsIllustration Showing a Horizontal Termination Installation Vertical Direct Vent Installations Vertical Vent InstallationsCombustion Blower Dip Switch Settings Dip SwitchInstallation of Venting System Components Condensate Recommended Vent/Air Intake Terminal PositionJoint Connection Coping with CondensationIllustration Showing How to Shorten Vent Extensions Shortening of Vent ExtensionsVenting Parts & Dimensions Components Needed for Direct Vent ApplicationsVent Pipe Clamp, p/n Page Measure Dimension to Fit Illustration Showing How to Properly Cut a Vent ExtensionFinal Installation of the Vent System Illustration Showing How to Cut the Vertical Vent to Fit Cut the Vent to FitHigh Altitude Installations Mounting the Vent System Vertical DischargePage Venting Suppliers Manufacturer ProductSection VI GAS Connections Gas GAS Meter Size Natural GAS onlyGAS Pressure Regulation Specific CorrectionInitial Operation and Testing Installer only Section VII Electrical Connections Ladder Diagram Wiring Diagram for Tghe Models Temperature Controls Page Securing screw Wiring hole 21/32 Installation of Remote Controls OptionalIllustration Showing Where to Connect Remote Control Harness Resistance Connector Pin Nos Initial Operation and Testing of Controls Installer onlyTroubleshooting Electrical Wire ColorHeat Exchanger and Outgoing Water Temperature Thermistors Flame RodFrost Protection Amp FusesSection Viii Operating Instructions General Instructions To Fill the Water HeaterSequence of Operation What to do if YOU Smell GAS Lighting Instructions For Your Safety Read Before OperatingProperty damage, personal injury or loss of life Operation InstructionsTemperature Adjustment Turning OFF the Water Heater for AN Extended Period of TimePage Approximate TIME/TEMPERATURE Relationships in Scalds ScaldingFirst AID for Scalds Code Code DescriptionCode Code Description Thermal Fuse Code Code Description Nothing happens Section IX Maintenance Burner Flame AppearancePage Circulating Pump Water HeaterPage Section X Parts List TGHE-160I TGHE-199I Description QuantityPage TGHE-160I TGHE-199I Page TGHE-160I TGHE-199I Page TGHE-160I TGHE-199I Section XI Warranty What should you do to keep the warranty in effect? What will we do to correct problems?How do you get warranty assistance? What will we not do?Page Page Fax/215-641-1670 Parts Fax/215-641-2180