Bradford-White Corp TGHE-160I-N(X), TGHE-1991-N(X) Joint Connection, Coping with Condensation

Page 32

Table 8. Required Clearances for Venting.

*For clearances not specified in ANSI Z223.1 / NFPA 54 or CGA-B149 (latest editions), please use clearances in accordance with local installation codes and the requirements of the gas supplier .

**For other than Direct Vent Appliance, 4 ft (1.22 m) below or to side of opening; 1 ft (300 mm) above opening.

General Installation Instructions

Joint Connection

Figure 14. Illustration Showing How to Properly Connect Venting.

Firmly press the vent pipe sections together to ensure that the gaskets properly seal.

Coping with Condensation

Figure 15. Illustration Showing How to Ensure Proper Condensate Drainage.

Horizontal vent lengths must be pitched 3/4” per foot for proper condensate disposal.

32

Image 32
Contents TGHE-160I-NX & TGHE-199I-NX Table of Contents Page Page If YOU Smell GAS Section II Specifications ModelDimensions Pressure Drop psi Water Flow Rate gpm Section III Installation Instructions Remove Carton UnpackingWater Heater Location Mount Water Heater on the Wall State Regulations Important In the State of Massachusetts 248CMR 4.00Instructions for Connections Section IV Water ConnectionsWater Quality Page Approximate TIME/TEMPERATURE Relationships in Scalds Recommended Piping for a Basic Installation Recommended Piping for a Circulation Systems Recommended Piping for Power Failure Freeze Protection Recommended Piping for Freeze ProtectionPressure Relief Valve Page Page Section V Venting Venting Vent / Air Intake Terminal Locations Direct Vent Terminal LocationVenting System Installation Venting System LayoutPrior to the Installation of the EverHot Direct Vent System Horizontal Direct Vent InstallationsIllustration Showing a Horizontal Termination Installation Vertical Direct Vent Installations Vertical Vent InstallationsCombustion Blower Dip Switch Settings Dip SwitchInstallation of Venting System Components Condensate Recommended Vent/Air Intake Terminal PositionJoint Connection Coping with CondensationIllustration Showing How to Shorten Vent Extensions Shortening of Vent ExtensionsVenting Parts & Dimensions Components Needed for Direct Vent ApplicationsVent Pipe Clamp, p/n Page Measure Dimension to Fit Illustration Showing How to Properly Cut a Vent ExtensionFinal Installation of the Vent System Illustration Showing How to Cut the Vertical Vent to Fit Cut the Vent to FitHigh Altitude Installations Mounting the Vent System Vertical DischargePage Venting Suppliers Manufacturer ProductSection VI GAS Connections GAS Meter Size Natural GAS only GAS Pressure RegulationGas Specific CorrectionInitial Operation and Testing Installer only Section VII Electrical Connections Ladder Diagram Wiring Diagram for Tghe Models Temperature Controls Page Securing screw Wiring hole 21/32 Installation of Remote Controls OptionalIllustration Showing Where to Connect Remote Control Harness Initial Operation and Testing of Controls Installer only Troubleshooting ElectricalResistance Connector Pin Nos Wire ColorHeat Exchanger and Outgoing Water Temperature Thermistors Flame RodFrost Protection Amp FusesSequence of Operation Section Viii Operating InstructionsGeneral Instructions To Fill the Water Heater Lighting Instructions For Your Safety Read Before Operating Property damage, personal injury or loss of lifeWhat to do if YOU Smell GAS Operation InstructionsTemperature Adjustment Turning OFF the Water Heater for AN Extended Period of TimePage Approximate TIME/TEMPERATURE Relationships in Scalds ScaldingFirst AID for Scalds Code Code DescriptionCode Code Description Thermal Fuse Code Code Description Nothing happens Section IX Maintenance Burner Flame AppearancePage Circulating Pump Water HeaterPage Section X Parts List TGHE-160I TGHE-199I Description QuantityPage TGHE-160I TGHE-199I Page TGHE-160I TGHE-199I Page TGHE-160I TGHE-199I Section XI Warranty What will we do to correct problems? How do you get warranty assistance?What should you do to keep the warranty in effect? What will we not do?Page Page Fax/215-641-1670 Parts Fax/215-641-2180