HANDLE INSTALLATION

Manual backgroundDANGER

FLAMMBLE

Flammable Vapors

HANDLE INSTALLATION

For ease of handling and carrying, plugs are provided in the side of the shroud that can be removed and pipe handles inserted (see Figure 4).

Manual background Vapors from flammable liquids may explode and catch fire causing death or severe burns.

Do not use or store flammable products such as gasoline, solvents or adhe- sives in the same room or area near the water heater.

Keep flammable products:

1.far away from heater,

2.in approved containers,

3.tightly closed and

4.out of children's reach.

Water heater has a main burner and spark generator. The spark generator:

1.can be triggered at any time and

2.the spark will ignite flammable vapors.

Vapors:

1.cannot be seen,

2.are heavier than air,

3.go a long way on the floor and

4.can be carried from other rooms to the the electodes by air currents.

Remove plastic plugs from shroud side panels.

Screw a short length of 3/4” NPT pipe into the sides of the water heater.

Use the handles to move the water heater to the desired location.

Remove the handles.

Reinstall the plastic plugs in the shroud side panels.

Handle

Handle

Installation: Do not install the water heater where flammable products will be stored or used.

This water heater must not be installed directly on carpeting. Carpeting must be protected by metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3in. (7.6cm) in any direction, or if the appliance is installed in an alcove or closet, the entire floor must be covered by the panel. Failure to heed this warning may result in a fire hazard.

FIGURE 4

www.hotwater.com

13

Image 13
Contents POWER VENT GAS MODELS For Your SafetyInstallation and Operating Manual HYBRID GAS WATER HEATERSIMPORTANT INFORMATION TABLE OF CONTENTSIMPORTANT DEFINITIONS SAFE INSTALLATION, USE AND SERVICEGENERAL SAFETY DANGER INTRODUCTION Page GET TO KNOW YOUR WATER HEATER - GAS MODELS REPLACEMENT PARTS AND DELIMING PRODUCTSROUGH IN DIMENSIONS INSTALLATION CONSIDERATIONSINSTALLATION REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS Water Potable Heating All models are considered WATER PIPING - MIXING VALVE USAGEFACTS TO CONSIDER ABOUT LOCATION HANDLE INSTALLATION Access To EARTHQUAKE ZONESTop Casing Front ScrewsAPPLIANCES IN UNCONFINED SPACES COMBUSTION AIR AND VENTILATIONAPPLIANCES IN CONFINED SPACES B. ALL AIR FROM OUTDOORS See Figures 12, 13 and WATER PIPING CHEMICAL VAPOR CORROSIONCLOSED WATER SYSTEMS THERMAL EXPANSIONTEMPERATURE-PRESSURE RELIEF VALVE HARD WATERT&P Valve and Pipe Insulation if supplied SEDIMENT TRAPS GAS PIPINGGAS LINE PURGING HIGH ALTITUDE INSTALLATIONSFLOODING/FREEZING FILLING THE WATER HEATERVENT PIPE TERMINATION If using 2 inch vent pipePLANNING THE VENT SYSTEM RODENT SCREEN INSTALL INTO ELBOW GROUND LEVEL OR MAXIMUM SNOW LINE If using 3 inch vent pipeTERMINATION ELBOW ELBOW STRAPVENT TERMINAL INSTALLATION, SIDEWALL INSTALLATION OF VENT SYSTEMCONDENSATE CONDENSATION WARNINGINSTALLATION SEQUENCE SEQUENCE OF INSTALLATIONSVent terminals supplied with heater must be used INSTALLATION OF VERTICAL VENT SYSTEM INSTALLATION OF VENT SYSTEM, SIDEWALLVENT PIPE PREPARATION STEP A RECOMMENDED BRUSH* SIZE FOR PRIMER AND CEMENT APPLICATIONSSTEP B STEP E U.S. POWER VENTSTEP F STEP G CONNECTION TO VENT PIPEVENT HOODS MAY BE EXTREMELY HOT DURING OPERATION CALIBRATION ELECTRICAL CONNECTIONSFIGURE 33a “OFF”, “up”DISPLAY PANEL OPERATING INSTRUCTIONSNumeric Display DISCONNECTION WHEN SERVICING CAUTION LABEL ALL WIRES PRIOR TOCONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUSFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONSOPERATING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCESTATE HEAT CYCLE DEFINITIONSDESCRIPTION TEMPERATURE REGULATION Temperature Probes UNIQUE HYBRID FEATURESWater Circulation Pump Line Voltage Monitor Detection of Failure to Maintain Desired Constant Temperature CONSTANT OUTPUT TEMPERATURE CONTROLSTART UP CONDITIONS OPERATIONAL CONDITIONSHOUSEKEEPING MAINTENANCEVENTING SYSTEM INSPECTION BURNER OPERATION AND INSPECTIONCLEANING THE INLET WATER FILTER ANODE ROD REPLACEMENTTEMPERATURE-PRESSURE RELIEF VALVE OPERATION MOTORSFLUSHING THE HEAT EXCHANGER LIME BUILD- UP CLEANING THE HEAT ENGINEDRAINING THE TANK FAULT INDICATION AND ERROR CODESDiagnostic DIAGNOSTIC DISPLAYCode and DisplayedLockout FaultCause RemedyLockout FaultCode DescriptionLockout TROUBLESHOOTING Check if there is any error code on WHEN THE TAP IS OPENEDb.The unit display is an error code system installed, or there is aLEAKAGE CHECKPOINTS SERVICEITEM # PARTS IDENTIFICATIONA Baffle, Flue B Hot Water Outlet Nipple w/ Anode, Heat Trap AB C DEF G T SH R I Q P KIT # REPLACEMENT PARTS DESCRIPTIONSERVICE AND LABOR RESPONSIBILITY LIMITED RESIDENTIAL GAS WARRANTYCLAIM PROCEDURE CONDITIONS AND EXCEPTIONSPage Page 500 TENNESSEE WALTZ PARKWAY ASHLAND CITY, TN PHONE 1-800-433-2545 FAX