A.O. Smith HYB-90N Diagnostic Display, Code and, Displayed, Measurement, Units, Description

Page 47
DIAGNOSTIC DISPLAY

DIAGNOSTIC DISPLAY

By simultaneously pressing the “Mode” and “down arrow” buttons for 3 seconds the unit will allow access to the diagnostic mode.

In diagnostic mode, using the up/down arrow allows for cycling between diagnostic codes. The numeric display will show the diagnostic code for 1 second, followed by the actual measurement displayed for 3 seconds. For example, H01

-105 represents the diagnostic code of “H01” and the value of “105” is the inlet water temperature measurement. The display will continue to show the diagnostic code and the measurement value unless the up or down arrows are pressed to switch to the next item (see Table 4). If no buttons are pressed for 30 seconds the unit will revert back to operation mode where the set-point temperature is displayed.

 

 

Code and

 

Displayed

 

 

Diagnostic

 

Measurement

Units

 

 

Description

characters

Meaning

Remarks

Code

Display

(Example of)

 

(Example of)

 

 

 

 

Format

 

 

 

 

 

 

 

 

 

H01

Inlet Water

H01 – xxx

ºC or ºF

041 or 105

41ºC or 105ºF

ºC LED or ºF

 

Temperature

 

 

 

 

LED turned ON

H02

Heat engine outlet

H02 – xxx

ºC or ºF

041 or 105

41ºC or 105ºF

ºC LED or ºF

 

water temperature

 

 

 

 

LED turned ON

H03

Storage tank

H03 – xxx

ºC or ºF

041 or 105

41ºC or 105ºF

ºC LED or ºF

 

temperature

 

 

 

 

LED turned ON

H04

Heat engine water

H04 – xxx

litres/minute

056

5.6 litres/minute

1 litre =

 

flow rate

 

 

 

(1.48 Gallons/

0.264 Gallons

 

 

 

 

 

minute)

1 gallon =

 

 

 

 

 

 

3.78 litres

H05

Fan Speed

H05 - __x – xxx

rpm

006_511

6511 rpm

rpm=rotations

 

 

 

 

 

 

per minute

H06

Fan Current

H06 - __x – xxx

mA

001_456

1456 mA

mA=milliampers

 

 

 

 

 

(1.456A)

 

H07

Proportional Valve

H07 – xxx

mA

178

178 mA

mA=milliampers

 

Current

 

 

 

 

 

H08

Total Heating

H08 – xxx – xxx

hours

001_234

1234 hours

 

 

Time

 

 

 

(51.41 days)

 

H09

Total Cycles

H09 – xxx – xxx

heating cycles

000_459

459 heating

 

 

 

 

 

 

cycles

 

H10

Heat Engine

H10 – xxx

KBtu/hour

100

100 KBtu/hour

 

 

Rated Output

 

 

 

 

 

H11

Current Error

H11 – xxx

N/A

E00

Proper operation

 

 

Code (See Fault

 

 

 

- No error

 

 

Code Table)

 

 

 

 

 

H12 – H20

Error Code

Hxx – xxx

N/A

E28

Ignition failure

The most

 

History, From the

 

 

 

 

recent error

 

Most Recent to

 

 

 

 

corresponds

 

the Least Recent

 

 

 

 

to H12 and the

 

(See Fault Code

 

 

 

 

least recent to

 

Table)

 

 

 

 

H20

H21

Software

H21 – xxx – xxx

N/A

002_025

Software release

For the main

 

Release Number

 

 

 

number 2.25

controller board

 

(CWHCB)

 

 

 

 

 

H22

Software Release

H22 – xxx – xxx

N/A

002_009

Software release

For the display

 

Number (UIM)

 

 

 

number 2.09

board

H23

Configuration File

H23 – xxx – xxx

N/A

000_006

Configuration file

 

 

Number

 

 

 

number 6

 

TABLE 4

www.hotwater.com

47

Image 47
Contents HYBRID GAS WATER HEATERS For Your SafetyPOWER VENT GAS MODELS Installation and Operating ManualIMPORTANT INFORMATION TABLE OF CONTENTSIMPORTANT DEFINITIONS SAFE INSTALLATION, USE AND SERVICEGENERAL SAFETY DANGER INTRODUCTION Page GET TO KNOW YOUR WATER HEATER - GAS MODELS REPLACEMENT PARTS AND DELIMING PRODUCTSROUGH IN DIMENSIONS INSTALLATION CONSIDERATIONSINSTALLATION REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS Water Potable Heating All models are considered WATER PIPING - MIXING VALVE USAGEFACTS TO CONSIDER ABOUT LOCATION HANDLE INSTALLATION Access To EARTHQUAKE ZONESTop Casing Front ScrewsAPPLIANCES IN CONFINED SPACES COMBUSTION AIR AND VENTILATIONAPPLIANCES IN UNCONFINED SPACES B. ALL AIR FROM OUTDOORS See Figures 12, 13 and THERMAL EXPANSION CHEMICAL VAPOR CORROSIONWATER PIPING CLOSED WATER SYSTEMSTEMPERATURE-PRESSURE RELIEF VALVE HARD WATERT&P Valve and Pipe Insulation if supplied SEDIMENT TRAPS GAS PIPINGFILLING THE WATER HEATER HIGH ALTITUDE INSTALLATIONSGAS LINE PURGING FLOODING/FREEZINGPLANNING THE VENT SYSTEM If using 2 inch vent pipeVENT PIPE TERMINATION ELBOW STRAP If using 3 inch vent pipeRODENT SCREEN INSTALL INTO ELBOW GROUND LEVEL OR MAXIMUM SNOW LINE TERMINATION ELBOWCONDENSATION WARNING INSTALLATION OF VENT SYSTEMVENT TERMINAL INSTALLATION, SIDEWALL CONDENSATEVent terminals supplied with heater must be used SEQUENCE OF INSTALLATIONSINSTALLATION SEQUENCE INSTALLATION OF VERTICAL VENT SYSTEM INSTALLATION OF VENT SYSTEM, SIDEWALLVENT PIPE PREPARATION STEP B RECOMMENDED BRUSH* SIZE FOR PRIMER AND CEMENT APPLICATIONSSTEP A STEP G CONNECTION TO VENT PIPE U.S. POWER VENTSTEP E STEP FVENT HOODS MAY BE EXTREMELY HOT DURING OPERATION “OFF”, “up” ELECTRICAL CONNECTIONSCALIBRATION FIGURE 33aDISPLAY PANEL OPERATING INSTRUCTIONSNumeric Display CAUSE IMPROPER AND DANGEROUS CAUTION LABEL ALL WIRES PRIOR TODISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CANTO TURN OFF GAS TO APPLIANCE LIGHTING INSTRUCTIONSFOR YOUR SAFETY READ BEFORE LIGHTING OPERATING INSTRUCTIONSDESCRIPTION HEAT CYCLE DEFINITIONSSTATE TEMPERATURE REGULATION Temperature Probes UNIQUE HYBRID FEATURESWater Circulation Pump Line Voltage Monitor OPERATIONAL CONDITIONS CONSTANT OUTPUT TEMPERATURE CONTROLDetection of Failure to Maintain Desired Constant Temperature START UP CONDITIONSBURNER OPERATION AND INSPECTION MAINTENANCEHOUSEKEEPING VENTING SYSTEM INSPECTIONMOTORS ANODE ROD REPLACEMENTCLEANING THE INLET WATER FILTER TEMPERATURE-PRESSURE RELIEF VALVE OPERATIONFLUSHING THE HEAT EXCHANGER LIME BUILD- UP CLEANING THE HEAT ENGINEDRAINING THE TANK FAULT INDICATION AND ERROR CODESDisplayed DIAGNOSTIC DISPLAYDiagnostic Code andRemedy FaultLockout CauseDescription FaultLockout CodeDescription TROUBLESHOOTING system installed, or there is a WHEN THE TAP IS OPENEDCheck if there is any error code on b.The unit display is an error codeLEAKAGE CHECKPOINTS SERVICEA Baffle, Flue B Hot Water Outlet Nipple w/ Anode, Heat Trap PARTS IDENTIFICATIONITEM # AB C DEF G T SH R I Q P KIT # REPLACEMENT PARTS DESCRIPTIONCONDITIONS AND EXCEPTIONS LIMITED RESIDENTIAL GAS WARRANTYSERVICE AND LABOR RESPONSIBILITY CLAIM PROCEDUREPage Page 500 TENNESSEE WALTZ PARKWAY ASHLAND CITY, TN PHONE 1-800-433-2545 FAX