SAFE INSTALLATION, USE AND SERVICE

SAFE INSTALLATION, USE AND SERVICE

Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.

Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others who install, use or service this water heater.

All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message and how to avoid the risk of injury.

The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of substances known to the State of California to cause cancer, birth defects, or other reproductive harm, and requires businesses to warn of potential exposure to such substances.

This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm. This appliance can cause low level exposure to some of the substances listed.

IMPORTANT DEFINITIONS

Qualified Installer or Service Agency: Installation and service of this water heater requires ability equivalent to that of a Qualified Agency (as defined by ANSI below) in the field involved. Installation skills such as plumbing, air supply, venting, gas supply, electrical supply are required in addition to electrical testing skills when performing service.

ANSI Z223.1 2006 Sec. 3.3.83: “Qualified Agency” - “Any individual, firm, corporation or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing or replacement of gas piping or (b) the connection, installation, testing, repair or servicing of appliances and equipment; that is experienced in such work; that is familiar with all precautions required; and that has complied with all the requirements of the authority having jurisdiction.”.

Gas Supplier: The Natural Gas or Propane Utility or service who supplies gas for utilization by the gas burning appliances within this application. The gas supplier typically has responsibility for the inspection and code approval of gas piping up to and including the Natural Gas meter or Propane storage tank of a building.

www.hotwater.com

3

Image 3
Contents HYBRID GAS WATER HEATERS For Your SafetyPOWER VENT GAS MODELS Installation and Operating ManualIMPORTANT INFORMATION TABLE OF CONTENTSIMPORTANT DEFINITIONS SAFE INSTALLATION, USE AND SERVICEGENERAL SAFETY DANGER INTRODUCTION Page GET TO KNOW YOUR WATER HEATER - GAS MODELS REPLACEMENT PARTS AND DELIMING PRODUCTSROUGH IN DIMENSIONS INSTALLATION CONSIDERATIONSINSTALLATION REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS Water Potable Heating All models are considered WATER PIPING - MIXING VALVE USAGEFACTS TO CONSIDER ABOUT LOCATION HANDLE INSTALLATION Access To EARTHQUAKE ZONESTop Casing Front ScrewsCOMBUSTION AIR AND VENTILATION APPLIANCES IN UNCONFINED SPACESAPPLIANCES IN CONFINED SPACES B. ALL AIR FROM OUTDOORS See Figures 12, 13 and THERMAL EXPANSION CHEMICAL VAPOR CORROSIONWATER PIPING CLOSED WATER SYSTEMSTEMPERATURE-PRESSURE RELIEF VALVE HARD WATERT&P Valve and Pipe Insulation if supplied SEDIMENT TRAPS GAS PIPINGFILLING THE WATER HEATER HIGH ALTITUDE INSTALLATIONSGAS LINE PURGING FLOODING/FREEZINGIf using 2 inch vent pipe VENT PIPE TERMINATIONPLANNING THE VENT SYSTEM ELBOW STRAP If using 3 inch vent pipeRODENT SCREEN INSTALL INTO ELBOW GROUND LEVEL OR MAXIMUM SNOW LINE TERMINATION ELBOWCONDENSATION WARNING INSTALLATION OF VENT SYSTEMVENT TERMINAL INSTALLATION, SIDEWALL CONDENSATESEQUENCE OF INSTALLATIONS INSTALLATION SEQUENCEVent terminals supplied with heater must be used INSTALLATION OF VERTICAL VENT SYSTEM INSTALLATION OF VENT SYSTEM, SIDEWALLVENT PIPE PREPARATION RECOMMENDED BRUSH* SIZE FOR PRIMER AND CEMENT APPLICATIONS STEP ASTEP B STEP G CONNECTION TO VENT PIPE U.S. POWER VENTSTEP E STEP FVENT HOODS MAY BE EXTREMELY HOT DURING OPERATION “OFF”, “up” ELECTRICAL CONNECTIONSCALIBRATION FIGURE 33aDISPLAY PANEL OPERATING INSTRUCTIONSNumeric Display CAUSE IMPROPER AND DANGEROUS CAUTION LABEL ALL WIRES PRIOR TODISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CANTO TURN OFF GAS TO APPLIANCE LIGHTING INSTRUCTIONSFOR YOUR SAFETY READ BEFORE LIGHTING OPERATING INSTRUCTIONSHEAT CYCLE DEFINITIONS STATEDESCRIPTION TEMPERATURE REGULATION Temperature Probes UNIQUE HYBRID FEATURESWater Circulation Pump Line Voltage Monitor OPERATIONAL CONDITIONS CONSTANT OUTPUT TEMPERATURE CONTROLDetection of Failure to Maintain Desired Constant Temperature START UP CONDITIONSBURNER OPERATION AND INSPECTION MAINTENANCEHOUSEKEEPING VENTING SYSTEM INSPECTIONMOTORS ANODE ROD REPLACEMENTCLEANING THE INLET WATER FILTER TEMPERATURE-PRESSURE RELIEF VALVE OPERATIONFLUSHING THE HEAT EXCHANGER LIME BUILD- UP CLEANING THE HEAT ENGINEDRAINING THE TANK FAULT INDICATION AND ERROR CODESDisplayed DIAGNOSTIC DISPLAYDiagnostic Code andRemedy FaultLockout CauseDescription FaultLockout CodeDescription TROUBLESHOOTING system installed, or there is a WHEN THE TAP IS OPENEDCheck if there is any error code on b.The unit display is an error codeLEAKAGE CHECKPOINTS SERVICEPARTS IDENTIFICATION ITEM #A Baffle, Flue B Hot Water Outlet Nipple w/ Anode, Heat Trap AB C DEF G T SH R I Q P KIT # REPLACEMENT PARTS DESCRIPTIONCONDITIONS AND EXCEPTIONS LIMITED RESIDENTIAL GAS WARRANTYSERVICE AND LABOR RESPONSIBILITY CLAIM PROCEDUREPage Page 500 TENNESSEE WALTZ PARKWAY ASHLAND CITY, TN PHONE 1-800-433-2545 FAX