A.O. Smith HYB-90N warranty Condensate, Condensation Warning, Installation Of Vent System

Page 25
CONDENSATE

CONDENSATE

This water heater is a condensing unit and requires a drain to be located in close proximity to allow the condensate to drain safely. The condensate drains from the unit at the exhaust tee located at the bottom of the unit (see Figure 22). Condensate from this water heater is mildly acidic. Please note that some local codes require that condensate is treated by using a pH neutralizing filter prior to disposal.

Caution must be used to ensure that the drain is free and clear of debris and will not allow backflow through the condensate tube. Consideration must be given to avoid freezing of the condensate lines which could result in excessive build up of condensate inside the water heater. Waterproof heat tape may be required to prevent freezing of the condensate lines. Please ensure that the outlet of the condensate drain does not create a slippery condition which could lead to personal injury.

To operate properly and prevent exhaust gases from escaping through the condensate trap, the trap must contain some water. Before being started for the first time, water must be added to the trap. Remove the condensate tube (if installed) and add water to the trap through the hole for the condensate tube until it flows from the hole. (Re)install the condensate tube.

CONDENSATION WARNING:

THIS WATER HEATER IS A CONDENSING UNIT AND REQUIRES A DRAIN TO BE LOCATED IN CLOSE PROXIMITY TO ALLOW CONDENSATE TO DRAIN SAFELY. THE CONDENSATE DRAINS FROM UNIT AT THE EXHAUST ELBOW LOCATED AT BOTTOM OF UNIT.

NOTE: IT IS IMPORTANT THAT THE CONDENSATE TUBE NOT BE ELEVATED ABOVE THE CONDENSATE TRAP OUTLET (SEE FIGURE 22). CONDENSATE BUILD-UP WILL BLOCK THE EXHAUST OUTLET, WHICH WILL CAUSE IMPROPER OPERATION. WITH SOME INSTALLATIONS IT IS RECOMMEND TO INSTALL A CONDENSATE PUMP.

NOTE: Barbed fitting not required if hard piping is used to drain condensate.

VENTING

EXHAUST

ELBOW

BARBED FITTING

CONDENSATE

TRAP

DRAIN PAN - ROUTE

TO SUITABLE DRAIN

CONDENSATE TUBE -

SLOPE TO SUITABLE DRAIN

NOTE: THE CONDENSATE TUBE

MUST BE BELOW EXHAUST ELBOW.

FIGURE 22

INSTALLATION OF VENT SYSTEM

Before beginning installation of piping system thoroughly read the “Vent Pipe Preparation” section of this manual.

If you are installing your system so that it vents through roof, please refer to the section titled “Installation Of Vertical Vent System”.

Ensure the vent length is long enough that the outside air will not cause the water heater to freeze.

VENT TERMINAL INSTALLATION, SIDEWALL

1.Install the vent terminal by using the cover plate as a template to mark the hole for the vent pipe to pass through the wall. BEWARE OF CONCEALED WIRING AND PIPING INSIDE THE WALL.

2.If the Vent Terminal is being installed on the outside of a finished wall, it may be easier to mark both the inside and outside wall. Align the holes by drilling a hole through the center of the template from the inside through to the outside. The template can now be positioned on the outside wall using the drilled hole as a centering point for the template.

3.A) MASONRY SIDE WALLS

Chisel an opening approximately 1/2 in. (1.3cm) larger than the marked circle.

B)WOODEN SIDE WALLS

Drill a pilot hole approximately 1/4 in. (0.64cm) outside of the marked circle. This pilot hole is used as a starting point for a saws-all or sabre saw blade. Cut around the marked circle staying approximately 1/4 in. (0.64cm) outside of the line. (This will allow the vent to easily slide through the opening. The resulting gap will be covered up by the Vent Terminal cover plate.) Repeat this step on inside wall if necessary.

www.hotwater.com

25

Image 25
Contents POWER VENT GAS MODELS For Your SafetyInstallation and Operating Manual HYBRID GAS WATER HEATERSIMPORTANT INFORMATION TABLE OF CONTENTSIMPORTANT DEFINITIONS SAFE INSTALLATION, USE AND SERVICEGENERAL SAFETY DANGER INTRODUCTION Page GET TO KNOW YOUR WATER HEATER - GAS MODELS REPLACEMENT PARTS AND DELIMING PRODUCTSROUGH IN DIMENSIONS INSTALLATION CONSIDERATIONSINSTALLATION REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS Water Potable Heating All models are considered WATER PIPING - MIXING VALVE USAGEFACTS TO CONSIDER ABOUT LOCATION HANDLE INSTALLATION Access To EARTHQUAKE ZONESTop Casing Front ScrewsAPPLIANCES IN UNCONFINED SPACES COMBUSTION AIR AND VENTILATIONAPPLIANCES IN CONFINED SPACES B. ALL AIR FROM OUTDOORS See Figures 12, 13 and WATER PIPING CHEMICAL VAPOR CORROSIONCLOSED WATER SYSTEMS THERMAL EXPANSIONTEMPERATURE-PRESSURE RELIEF VALVE HARD WATERT&P Valve and Pipe Insulation if supplied SEDIMENT TRAPS GAS PIPINGGAS LINE PURGING HIGH ALTITUDE INSTALLATIONSFLOODING/FREEZING FILLING THE WATER HEATERVENT PIPE TERMINATION If using 2 inch vent pipePLANNING THE VENT SYSTEM RODENT SCREEN INSTALL INTO ELBOW GROUND LEVEL OR MAXIMUM SNOW LINE If using 3 inch vent pipeTERMINATION ELBOW ELBOW STRAPVENT TERMINAL INSTALLATION, SIDEWALL INSTALLATION OF VENT SYSTEMCONDENSATE CONDENSATION WARNINGINSTALLATION SEQUENCE SEQUENCE OF INSTALLATIONSVent terminals supplied with heater must be used INSTALLATION OF VERTICAL VENT SYSTEM INSTALLATION OF VENT SYSTEM, SIDEWALLVENT PIPE PREPARATION STEP A RECOMMENDED BRUSH* SIZE FOR PRIMER AND CEMENT APPLICATIONSSTEP B STEP E U.S. POWER VENTSTEP F STEP G CONNECTION TO VENT PIPEVENT HOODS MAY BE EXTREMELY HOT DURING OPERATION CALIBRATION ELECTRICAL CONNECTIONSFIGURE 33a “OFF”, “up”DISPLAY PANEL OPERATING INSTRUCTIONSNumeric Display DISCONNECTION WHEN SERVICING CAUTION LABEL ALL WIRES PRIOR TOCONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUSFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONSOPERATING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCESTATE HEAT CYCLE DEFINITIONSDESCRIPTION TEMPERATURE REGULATION Temperature Probes UNIQUE HYBRID FEATURESWater Circulation Pump Line Voltage Monitor Detection of Failure to Maintain Desired Constant Temperature CONSTANT OUTPUT TEMPERATURE CONTROLSTART UP CONDITIONS OPERATIONAL CONDITIONSHOUSEKEEPING MAINTENANCEVENTING SYSTEM INSPECTION BURNER OPERATION AND INSPECTIONCLEANING THE INLET WATER FILTER ANODE ROD REPLACEMENTTEMPERATURE-PRESSURE RELIEF VALVE OPERATION MOTORSFLUSHING THE HEAT EXCHANGER LIME BUILD- UP CLEANING THE HEAT ENGINEDRAINING THE TANK FAULT INDICATION AND ERROR CODESDiagnostic DIAGNOSTIC DISPLAYCode and DisplayedLockout FaultCause RemedyLockout FaultCode DescriptionLockout TROUBLESHOOTING Check if there is any error code on WHEN THE TAP IS OPENEDb.The unit display is an error code system installed, or there is aLEAKAGE CHECKPOINTS SERVICEITEM # PARTS IDENTIFICATIONA Baffle, Flue B Hot Water Outlet Nipple w/ Anode, Heat Trap AB C DEF G T SH R I Q P KIT # REPLACEMENT PARTS DESCRIPTIONSERVICE AND LABOR RESPONSIBILITY LIMITED RESIDENTIAL GAS WARRANTYCLAIM PROCEDURE CONDITIONS AND EXCEPTIONSPage Page 500 TENNESSEE WALTZ PARKWAY ASHLAND CITY, TN PHONE 1-800-433-2545 FAX