is
C13 Concentric wall flue terminal specifications
Subject |
| Description | |
|
|
| |
Wall flue terminal set: | Art. No. | 0302 504 1 | |
• 1x Wall flue terminal (incl. wall flange |
|
| |
Construction | Concentric | ||
& clamping ring) |
|
| |
Manufacturer | Muelink & Grol | ||
• 1x Pipe 500 mm | |||
|
| ||
Type | M2000 MDV SEC | ||
• 1x Bend 90° | |||
|
| ||
|
|
| |
Pipe material | Construction | Concentric | |
|
|
| |
| Chimney flue | ||
|
|
| |
| Air supply | ||
|
|
| |
Pipe diameters | Chimney flue | Ø 100 mm | |
|
|
| |
| Air supply | Ø 150 mm | |
|
|
|
(1) No other wall flue terminal is permitted. Use this item number to order the wall conduit set from supplier, manufacturer or wholesaler.
C33 concentric roof flue terminal specifications
Subject |
| Description | |
|
|
| |
Roof flue terminal set: | Art. No. | 0304 423 1 | |
• 1x Wall flue terminal (incl. clamping |
|
| |
Construction | Concentric | ||
ring) | |||
|
| ||
Manufacturer | Muelink & Grol | ||
• 1x Pipe 1000 mm | |||
|
| ||
Type | M2000 DDV | ||
• 1x Mounting flange | |||
|
| ||
|
|
| |
Pipe material | Construction | Concentric | |
|
|
| |
| Chimney flue | ||
|
|
| |
| Air supply | ||
|
|
| |
Pipe diameters | Chimney flue | Ø 100 mm | |
|
|
| |
| Air supply | Ø 150 mm | |
|
|
|
(1) No other roof flue terminal is permitted. Use this item number to order the roof conduit set from supplier,manufacturer or wholesaler.
3.9.4Parallel connections
The table states the maximum pipe lengths for parallel systems. The maximum pipe length depends on the chosen diameter.
Warning
Install flue component pipe runs with a
Chimney flue requirements for parallel systems |
|
| ||
|
|
|
|
|
Appliance | Diameter1 | Maximum | Lequivalent | Lequivalent |
|
| total length | 90° bend | bend 45° |
SGE 40 |
|
|
|
|
|
|
|
|
|
SGE 60 | 100 mm | 25 m | 4.6 m | 1.2 m |
|
|
|
|
|
SGE 40 |
|
|
|
|
|
|
|
|
|
SGE 60 | 130 mm | 100 m | 2.4 m | 1.4 m |
|
|
|
|
|
1) Parallel systems with diameter of 130 mm or 150 mm. If the maximum total | ||||
length for a diameter of 130 mm is insufficient, 150 mm diameter must be | ||||
used. Any diameter enlargement must be carried out on both air supply and | ||||
chimney flue. |
|
|
|
|
|
|
|
|
|
Instruction manual SGE | 33 |