6.2Draining vented installations
1.Activate the MENU with .
2.Position the cursor in front of OFF.
3.Confirm OFF with .
4.Wait until the fan has stopped. The symbol is then dimmed.
Caution
Failure to wait until the fan stops purging can cause damage to the appliance.
5.Switch the appliance OFF (position 0) using the ON/OFF switch on the control panel.
6.Isolate the water heater from the power supply by putting the isolator between the appliance and the mains power supply to position 0.
7.Shut off the gas supply (10).
8.Close the stop valve (11) in the hot water pipe.
9.Close the stop valve (4) between the water tank and the cold water inlet (A).
10.Open the drain valve (9).
11.Bleed the appliance (or installation) so that it drains completely.
6.3Draining solar heating system
6.3.1Draining glycol-filled system
Note
No special safety measures are required when working with the diluted glycol solution specified by the manufacturer. For more information about the fluid, please contact the manufacturer.
1. Activate the MENU with .
MENU »OFF ^ ON
ÈWEEK PROGRAM
2.Position the cursor in front of OFF.
3.Confirm OFF with .