Code + Description | Cause | Solution | Remark | |
|
|
|
| |
E01 (blocking error) | The temperature of the | None. This is a temporary message that may appear from time to |
| |
| water at the top of the | time, but will disappear automatically. |
| |
The temperature | tank is > 85 oC. |
|
|
|
protection at the top of |
|
|
|
|
the tank has been |
|
|
|
|
activated. |
|
|
|
|
|
|
|
|
|
E03 | The two temperature | 1. | Check sensor position and wiring. | To replace the necessary parts, you must contact your installation |
Error in temperature | sensors in the tank | 2. | If necessary, reset the electronic controller. Replace the sensor | engineer |
detect a differential of > |
| if the error persists. |
| |
sensor T at the top of | 10 oC over a period of |
|
| |
the tank.1 | at least 60 seconds. |
|
|
|
E04 | The two dummy | 1. | Check leads from dummy 1 and dummy 2. | To replace the necessary parts, you must contact your installation |
| sensors in the tank | 2. | If necessary, reset the electronic controller. Replace the dummy | engineer |
Error in dummy | detect a differential of > |
| ||
sensor(2). | 10 oC over a period of |
| sensor if the error persists. |
|
| at least 60 seconds. |
|
|
|
1) Temperature sensor T1 is a '2 in 1' sensor, T1 contains 2 NTCs for the
(2) The dummy sensor / flue gas sensor comprises dummy sensor / flue gas sensor 1 and dummy sensor / flue gas sensor 2.