GTO UL325 SERIES Disconnecting the Opener, Switch is OFF and the gate is not moving

Page 5

IMPORTANT SAFETY INSTRUCTIONS

Because automatic gate openers produce high levels of force, consumers need to know the potential hazards associated with improperly designed, installed, and maintained automated gate opener systems. Keep in mind that the gate opener is just one component of the total gate operating system. Each component must work in unison to provide the consumer with convenience, security, and safety.

This manual contains various safety precautions and warnings for the consumer. Because there are many possible applications of the gate opener, the safety precautions and warnings contained in this manual cannot be completely exhaustive in nature. They do, however, provide an overview of the safe design, installation, and use of this product. CAREFULLY

READ AND FOLLOW ALL SAFETY PRECAUTIONS, WARNINGS, AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE SYSTEM DESIGN, INSTALLATION, AND USE OF THIS PRODUCT.

Precautions and warnings in this manual are identified with this warning symbol. The symbol identifies conditions that can result in damage to the opener or its components, serious injury, or death.

Because GTO automatic gate openers are only part of the total gate operating system, it is the responsibility of the consumer to ensure that the total system is safe for its intended use.

To Manually Open and Close the Gate, Follow the Procedure Below:

CAUTION: The gate will move freely and uncontrolled when the gate opener is removed from the gate. ONLY disconnect the opener when the opener power

switch is OFF and the gate is NOT moving.

Disconnecting the Opener

1.Turn opener power switch OFF.

2.Remove hairpin clip, clevis pin, and bushing from the front mounting point.

3.Remove the opener from the mount.

The gate can be opened and closed manually when the opener is disconnected.

Front Mount

Clevis Pin

Gate Bracket

IMPORTANT: NEVER allow opener arm to hang by the front mount - it will break from the arm weight.

CAUTION: Because the Mighty Mule gate opener is battery powered, disconnect the opener ONLY when the power switch on the opener is turned OFF. Unplugging the transformer does not turn power to the opener OFF.

Bushing

Hairpin Clip

NOTE: Substitute a Pin Lock (FM133) for the clevis pin on the front mount only of the gate opener to prevent unauthorized removal of the opener from the gate (see Accessory Catalog).

1

Image 5
Contents 350 Installation Manual forPlace of Purchase When You Know Multiply By To Find SymbolTable of Contents Please Read this First Switch is OFF and the gate is not moving Disconnecting the OpenerEntrapment Zones for a Pull-To-Open Application For The ConsumerAny control device Within gray area II. During InstallationPull-To-Open Application III. After Installation Secondary Means of Protection Against Entrapment Entrapment Alarm UL 325 30A.1.1AEntrapment Protection Required Safety Precautions for GatesInstall Warning Signs 350 Hardware Bag Contents Tools Needed Mighty Mule 350 E-Z Gate Opener Technical SpecificationsPreparation of the Gate Installation OverviewPull-to-Open Gates Gate Opens into the Property StepRecommended Reinforcement Examples Installation of Mounting HardwarePost Bracket Assembly Closed Position Gate Bracket Mounting Examples Installing the Post Bracket Assembly and Gate BracketMounting the Opener Installation of the Closed Position StopCheck List Preparing to Activate the SystemSolar Panel and Gate Acticity Chart Powering the SystemConnecting the Battery MIghty Mule Wire Routing Important Deailed Wire Routing DiagramsImportant Information about LOW Voltage Wire Connecting the TransformerMake sure the exposed wires do not touch each other DIP Switches Connecting Solar PanelsMain DIP Switch Settings Modes DIP Switch #1 Push/Pull-to-OpenClosed Limit setting Setting the Closed Position LimitYour Mighty Mule 350 has two Limit Settings Setting Auto-Close Time Obstruction Sensitivity Potentiometer SettingTeach the New Code to Control Board Memory Set the transmitter DIP SwitchesRemove the Transmitter Cover Run the cable through PVC conduit to protect it from damage Installing the ReceiverIf not installing a contact sensor skip to next section Connecting Additional Safety DevicesContact Sensors safety edges If not installing a shadow loop skip to next section If not installing a non-contact sensor skip to next sectionNon-Contact Sensors photo beams Exit LoopAutomatic Gate Lock FM143 Connecting AccessoriesIf not connecting accessories skip to next section Mighty Mule Free Entry/Exit Loop Wiring Driveway Loops to the Mighty MuleMighty Mule Gate Opening Sensor FM138 When everything has been connected to the openerSwinging gates shall not open into public access areas Push to Open InstallationMODE2 LOCK/BEACON Setting the Open Position LimitTesting Your Open Limit Setting Power-Cycle Beep when attempt to run the unit No battery is connectedBeep with 2 seconds off Beeps with 2 seconds offGate Closes Then Opens Again on its Own Power LED GreenGate Opens Then Closes Again on its Own Charging LED RedGate Repair ServiceMail techsupport@gtoinc.com GTO, Inc., 3121 Hartsfield Road, Tallahassee, Florida, USAMASONRY, BRICK, or Rock etc. Columns Column Installation InformationAccessories Low Voltage Wire RB509

UL325 SERIES specifications

The GTO UL325 Series is a highly regarded line of gate operators, designed to meet the needs of both residential and commercial applications. With its commitment to safety, durability, and efficiency, the UL325 Series has set a standard in the industry for gate automation solutions.

One of the main features of the GTO UL325 Series is its robust safety mechanisms. The operators are designed to comply with the rigorous UL 325 safety standards, which is essential for ensuring user safety and preventing accidents during gate operation. This includes advanced features such as obstacle detection, which allows the system to sense when an object is in the path of the gate and stop or reverse the motion to prevent harm or damage.

The UL325 Series comes with a reliable and efficient motor that provides powerful performance while operating gates of various sizes and weights. This versatility allows it to be used for a range of gate types, including swing gates and sliding gates. The motors are also designed for quiet operation, minimizing noise disturbances in residential areas.

Additionally, the GTO UL325 Series incorporates smart technology features that enhance user experience. The built-in remote control system allows users to open and close their gates with the simple push of a button from a distance. Some models also support compatibility with smartphone apps, providing users with a modern and convenient way to control their gates from anywhere.

Durability is another characteristic of the GTO UL325 Series. Constructed with high-quality materials, these gate operators are built to withstand harsh weather conditions, making them suitable for various climates. This longevity ensures that users receive a reliable product that will serve their needs for years to come.

Another noteworthy aspect of the GTO UL325 Series is the ease of installation and maintenance. The operators are designed for straightforward installation, allowing both professionals and DIY enthusiasts to set them up with minimal hassle. Additionally, regular maintenance is simplified, with clear guidelines provided to ensure longevity and reliability.

In conclusion, the GTO UL325 Series is an exemplary choice for those seeking a reliable, safe, and technologically advanced gate operator. With its emphasis on safety, versatility, and user-friendly features, it stands out in the marketplace, making it an ideal solution for both residential and commercial gate automation needs. Investing in a GTO UL325 operator means investing in peace of mind, knowing that one has a dependable and efficient gating solution.