OPERATING PROCEDURE | PHOTOS |
2.Removing the fan motor
(1)Remove the top panel (five screws),the service panel (four screws), and the front panel (two screws).
(See Photo 1.)
(2)Disconnect the connector CN911 on the outdoor controller board.
(3)Remove the propeller. (4)Remove the fan motor.
3.Removing the | Photo 4 | ||||
(1)Remove the screws of the top panel, and remove it. | |||||
|
|
|
| ||
(See Photo 1.) |
|
|
|
| |
(2)Remove the service panel, rear panel, and connect cover |
|
|
|
| |
panel.Release refrigerant gas. |
| 4 way valve |
| ||
(3)Remove the electrical parts. (See Photo 2.) |
|
|
|
| |
|
|
|
| ||
(4)Detach the brazed joint of |
|
|
|
| |
(See Photo 4.) |
|
| R. V. coil | ||
|
|
|
|
|
Brazing Points
4.Removing the linear expansion valve | Photo 5 | |
(1)Remove the service panel. (See Photo 1.) | ||
| ||
(Gas release is not required if the unit is pumped down.) |
| |
(2)Remove the coil of linear expansion valve. |
| |
(3)Detach the brazed joint of linear expansion valve and pipe. |
|
LEV coils
Linear expansion valves
38