Symptom

 

Outdoor unit operates. (The compressor operates at reduced frequency.)

 

 

 

 

Display

Detecting method

Detecting method

Check points

 

 

 

 

d8

Frequency drop by current

When the outdoor unit input current exceeds 22.5 A, the compressor

 

(d8)

protection

operates at reduced frequency.

 

d9

Frequency drop by overload

When the compressor load exceeds the specified value, the compres-

These symptoms do not mean any

(d9)

protection

sor operates at reduced frequency.

abnormality of the product, but check the

 

 

 

 

Frequency drop by high pres-

When indoor pipe temperature exceeds 55˚C during heating, the com-

following points.

d7

sure protection

pressor operates at reduced frequency.

• Air filter clogging.

(d7)

 

 

• Amount of gas.

Frequency drop by defrosting

When the indoor pipe temperature falls to 6˚C or below during cooling,

• Short cycle of indoor/outdoor air flow.

 

in cooling

the compressor operates at reduced frequency.

 

 

 

 

 

d6

Frequency drop by discharge

When the discharge temperature exceeds 110˚C, the compressor oper-

 

(d6)

temperature protection

ates at reduced frequency.

 

d3

Frequency drop by high pres-

When the high pressure exceeds 2.75MPa (28 kgf/cm2-G), the com-

• Amount of gas.

(d3)

sure switch protection

pressor operates at reduced frequency. In addition, the fan speed

• Outdoor unit air passage.

 

changes.

 

 

 

 

 

d1

 

When the state with low discharge temperature of which 50˚C in COOL

Check the amount of gas.

Low discharge temperature

• Replace the outdoor controller board.

(d1)

protection

and 48.4 or less in HEAT for 20 minutes, the compressor operates con-

• Check the contact of LEV board connec-

 

tinuously.

tors.

 

 

 

 

 

 

 

 

 

 

 

Symptom

 

Outdoor unit operates.

 

 

 

 

 

Display

Detecting method

Detecting method

Check points

 

 

 

 

e7

Defrost thermistor abnormality

When a short or open circuit occurs in the defrost thermistor during

• Defrost thermistor characteristic.

(E7)

heating

• Contact of P. C. board connectors.

 

* In this case, the compressor continues to operate.

 

 

 

 

 

 

h4

Power factor detection abnor-

When the compressor power factor cannot be detected

• Compressor wiring.

(h4)

mality

* In this case, the compressor keeps running.

 

 

 

 

 

 

 

 

27

Image 27
Contents MXZ-32SV E1 MXZ-32SV E2 ContentsTechnical Changes Part Names and FunctionsOutdoor Unit Outdoor Unit Indoor / Outdoor Correspondence TableMXZ-32SV E1 , MXZ-32SV E2 Indoor Units Combination09+09+12 15.05 13.80 9.0 07+09 10.35 09+09+12 14.04 12.87 MXZ-32SV E1 , MXZ-32SV E2 Specification0dB = Test conditionsCooling DB35 WB24 Heating DBUnit mm Outlines and DimensionsModels MXZ-32SV- E1 Wiring DiagramUnitmm Refrigerant System DiagramCapacity and the Input Curves CWBCDB Outdoor UNITMXZ-32SV Capacity and input correction by inverter output frequencyHeat operation Outdoor low pressure and outdoor unit currentCurrent 10 15 20 10 15 20 Microprocessor Control Inverter Multi System ControlSSR61 LEV control Cool DRY Heat DRY Cool Operational frequency rangeDischarge temperature protection control Heat defrosting controlHigh or low pressure protection Refrigerant recovery control on heating Outdoor fan controlRelation between main sensor and actuator Lead wiring Housing point Troubleshooting procedure TroubleshootingInstruction of troubleshooting Before troubleshooting, check the followingLEV Troubleshooting check tableCheck the contact of LEV board connec Trouble criterion of main parts Outdoor unit does not operate. LED display Outdoor unit does not operate. LED display display OFFWhen cooling operation does not work. Start When heating operation does not work. StartCheck of LEV Check of thermistor Check of HPS Electronic control P.C.board Test Point Diagram and Voltage MXZ-32SV E1 , MXZ-32SV E2Outdoor FAN 230V AC Reversing Valve 230V AC Noise filter P.C.board MXZ-32SV E1Outdoor FAN 220V-240V AC Reversing Valve 220V-240V AC MXZ-32SV E2Relay P.C.board MXZ-32SV E1 MXZ-32SV E2 M P.C.board MXZ-32SV E1 MXZ-32SV E2Removing the compressor Photo Disassembly InstructionsOutdoor Unit Operating Procedure Photos MXZ-32SVRemoving the fan motor Removing the 4-way valve PhotoRemoving the linear expansion valve Photo Removing the reactor Operating Procedure PhotosOutdoor Unit Functional Parts MXZ-32SV E1 Parts ListMXZ-32SV E117 16 15 MXZ-32SV E2 Outdoor Unit Structural PartsSymbol Qty / unit Parts No Parts Name Wiring Remarks Accessory Parts MXZ-32SV E1 MXZ-32SV E2Outlet guide Different-diameter pipe