KitchenAid W10342488A VentingRequirements, Product Dimensions, Cabinet Dimensions

Page 5

Product Dimensions

9¹⁄₁₆" (23.0 cm)

21" (53.3 cm)

6" (15.2 cm)

6" (15.2 cm)

front edge to

 

damper centerline

 

9¹³⁄₁₆" (24.9 cm)

2³⁄₄" (7.0 cm)

¹⁵⁄₁₆" - 1³⁄₄" (2.4 cm - 4.4 cm)

trim extension

11¹⁄₁₆" (28.1 cm)

6⁷⁄₈" (17.5 cm) with screen extended

30" (76.2 cm) - 30" (76.2 cm) model 36" (91.4 cm) - 36" (91.4 cm) model

Cabinet Dimensions

15" (38.1 cm) min. upper cabinet height

30" (76.2 cm) or 36" (91.4 cm) min.

cabinet opening width

VentingRequirements

(vented models only)

Vent system must terminate to the outside, except for non-

vented (recirculating) installations.

Do not terminate the vent system in an attic or other enclosed

area.

Do not use a 4" (10.2 cm) laundry-type wall cap.

Use metal vent only. A rigid metal vent is recommended.

Plastic or metal foil vent is not recommended.

15" (38.1 cm) min. clearance upper cabinet to countertop

24" (61 cm) min.

32" (81 cm) suggested max.

bottom of cabinet to cooking surface

12" (30.5 cm) cabinet depth

The length of the vent system and number of elbows should

be kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61.0 cm) of straight

vent between the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

The vent system must have a damper. If the roof or wall cap

has a damper, do not use the damper supplied with the range

hood.

36" (91.4 cm) base cabinet height

Use clamps to seal all joints in the vent system.

Use caulking to seal exterior wall or roof opening around the

 

cap.

The size of the vent should be uniform.

5

Image 5
Contents SLIDE-OUT Range Hood Table of Contents/Table des matières Table DES Matières Range Hood SafetyImportant Safety Instructions Location Requirements Installation RequirementsToolsandParts Cabinet Dimensions Product DimensionsVentingRequirements For the most efficient and quiet operationMakeup air Cold weather installationsVenting Methods Example vent system 6 15.2 cmElectricalRequirements Installation InstructionsPrepareLocation Range Hood Cabinet CutoutVenting Outside Through the Wall Venting Outside Through the RoofUse caulking to seal around wire opening InstallRange Hood5 x 9.5 mm screws Install 2 5 x 18 mm adjusting screwsNon-Vented recirculating Installations Vented InstallationsElectrical Connection ConnecttheVentSystemControls Display Range Hood USEReplacing theHalogen Bulb CleaningRange Hood Care SEL0015013 Wiring DiagramAccessories Assistance or ServiceIntheU.S.A InCanadaThis limited warranty does not cover Kitchenaid Ventilation WarrantyVotre sécurité et celle des autres est très importante Sécurité DE LA Hotte D’ASPIRATIONImportantes Instructions DE Sécurité Outils et pièces Exigences DinstallationExigences demplacement Dimensions du placard Dimensions du produitExigencesconcernant l’évacuation Pour un fonctionnement efficace et silencieuxAir d’appoint Installations pour régions à climat froidMéthodes d’évacuation Calcul de la longueur effective du circuit dévacuationLes instructions suivantes SpécificationsélectriquesConnecter une section de câble en cuivre massif aux Conducteurs en queue de cochonPréparationdelemplacement Instructions D’INSTALLATIONOuverture découpée du placard pour la hotte Décharge à lextérieur, à travers le toitDécharge à lextérieur, à travers le mur Vis de montage de 3,5 x 9,5 mm Installationde lahotteRaccordementélectrique Installer 2 vis de réglage de 5 x 18 mmRaccordement du circuit dévacuation Installations avec décharge à l’extérieurInstallation sans décharge à l’extérieur recyclage Affichage Dispositifs decommandeUtilisation DE LA Hotte Nettoyage Remplacement delampoule àhalogèneEntretien DE LA Hotte Interface utilisateur Schémas DE CâblageAuCanada Assistance OU ServiceAccessoires La présente garantie limitée ne couvre pas Garantie DU Système DE Ventilation KitchenaidComposer le 1-800-422-1230. Au Canada, composer le W10342488A