5b.If chimney extension is
used: Attach the extension brackets as shown.
ceiling | |
(27 cm) |
|
brackets
(20.6 cm) | (20.6 cm) |
23" (58.4 cm) max.
12" (30.5 cm) min.
top of hood
Make sure that the screws are securely fastened to the wall.
6.Determine and make all necessary cuts in the wall for the vent system. Install the vent system before the canopy hood. See venting methods on Page 4, and hood vent opening dimensions on Page 6.
7. Determine the required height for the power supply cable and cut a
Use caulking to seal all openings.
Do Not turn on power until installation is completed.
8. Remove the terminal box cover from the canopy hood. Remove the power supply cable knockout using a
WARNING
Excessive Weight Hazard
Use two or more people to move and install range hood.
Failure to do so can result in back or other injury.
9. If roof or wall cap does not have a damper, attach damper to exhaust opening(s) on top of the hood using two
10. If 48" (121.9 cm) hood is to be connected to 10" (25.4 cm) round vent system, install the vent transition piece now.
bracket
| wall | |
V1 |
| |
| V2 | |
hood | mounting | |
screw | ||
|
36" (91.4 cm) hood has two brackets 42" (106.7 cm) hood has four brackets 48" (121.9 cm) hood has four brackets
11. The hood attaches to the wall by screws discussed earlier in the installation instructions at Step 5.The hood hangs from these screws by brackets inside the range hood. Before attempting to hang the hood, use a Phillips screwdriver to rotate the adjustment screw marked V1 counterclockwise to extend the brackets from the canopy.
Hang the range hood by inserting the brackets into the mounting screws as shown. Note: These screws must be installed into solid wood to support the weight of the hood as described in Step 5. Rotate the screws marked V1 to tighten the range hood against the wall.
Make sure that the range hood is securely tightened against the wall.
12. The brackets are also used to adjust the level of the canopy. Using a Phillips screwdriver, rotate the screw V2 to adjust the level of the canopy.
13. Connect vent system to hood. Seal all joints with duct tape.
14. If your installation uses the optional vent cover, fit the cover flanges over the brackets. If installation uses the chimney extension, fit the extension over the brackets. Install the upper section first, then fit the lower section over the upper section. Seal extension to hood with duct tape.
Electrical connection
WARNING
Electrical Shock Hazard
Disconnect power before making electrical connections.
Connect ground wire to green ground screw in terminal box.
Failure to do so can result in death or electrical shock.
15. Make electrical connection:
Connect the power supply cable to hood terminal box through the U.L.- or
Connect the white wire of the power supply cable with the white lead in the hood using a
Connect the power supply green ground wire under the green, ground screw.
Tighten conduit connector screws.
Replace the terminal box cover.
7