KitchenAid Dual Fuel Convection Range Gas Supply Requirements, Gas Supply Line, Type of Gas

Page 7

Gas Supply Requirements

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Gas Supply Line

Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape. With LP gas, piping or tubing size can be ½" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system.

Flexible metal appliance connector:

If local codes permit, a new CSA design-certified, 4 - 5 ft (122 - 152.4 cm) long, ⁵⁄₈" (1.6 cm) or

¾" (1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line.

A ½" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the range pressure regulator.

Do not kink or damage the flexible metal tubing when moving the range.

Rigid pipe connection:

Observe all governing codes and ordinances.

IMPORTANT: This installation must conform with all local codes and ordinances. In the absence of local codes, installation must conform with American National Standard, National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition or CAN/CGA B149 - latest edition.

IMPORTANT: Range cooktop must be connected to a regulated gas supply.

IMPORTANT: Leak testing of the range cooktop must be conducted according to the manufacturer’s instructions.

Type of Gas

Natural Gas:

This range is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas.

This range is factory set for use with Natural gas. The model/ serial rating plate located on the right vertical surface of the oven door frame has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.

LP Gas conversion:

Conversion must be done by a qualified service technician.

No attempt shall be made to convert the range cooktop from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. To convert to LP gas, use the LP gas conversion kit provided with your range. The parts for this kit are in the literature package supplied with the range.

The rigid pipe connection requires a combination of pipe fittings to obtain an in-line connection to the range. The rigid pipe must be level with the range connection. All strains must be removed from the supply and fuel lines so range will be level and in line.

Must include a manual shutoff valve:

The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the range.

B

A

C

A. Gas supply line

B. Shutoff valve “open” position

C. To range

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

7

Image 7
Contents 9760618B Pour utilisation résidentielle seulementTable DES Matières Range SafetyWhat to do if YOU Smell GAS Tools and Parts Installation RequirementsLocation Requirements Product Dimensions Cabinet Dimensions Mobile Home Additional Installation RequirementsMobile home installations require Electrical Requirements Canada Only Electrical Requirements U.S.A. OnlyElectrical Connection Gas Supply Line Gas Supply RequirementsType of Gas Unpack Range Installation InstructionsLevel Range Power Supply Install Anti-Tip BracketElectrical Connection Options Chart If your home has Go to Section WireAttaching the Island Trim Wire Cable from Home Power SupplyAttach Backguard or Island Trim Attaching the BackguardElectronic Ignition System Make Gas ConnectionReinstall Bottom Vent If range does not operate, check the following Wiring DiagramsComplete Installation Cooktop SchematicOven Schematic Page Votre sécurité et celle des autres est très importante Sécurité DE LA CuisinièrePièces nécessaires Exigences DinstallationOutillage et pièces Outillage nécessaireDimensions de lappareil Exigences demplacementDégagements de séparation à respecter Spécifications de l’installation électriqueType de gaz Canalisation de gaz Spécifications de l’alimentation en gazDéballage de la cuisinière Instructions DinstallationRéglage de laplomb de la cuisinière Fixation du dosseret ou de la garniture en îlot Installation de la bride antibasculementFixation du dosseret Fixation de la garniture en îlot Raccordement à la canalisation de gazCompléter le raccordement Système dallumage électronique Achever linstallation Réinstallation de lévent du fondSi la cuisinière ne fonctionne pas, contrôler ce qui suit Schéma de câblage de la table de cuisson Schémas DE CâblageSchéma de câblage du four All rights reserved