WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
TEMPERATURE SENSOR
Refer to page
1.Unplug dishwasher or disconnect power.
2.Disconnect the wire connector from the CHASSIS HARNESS terminals on the controller.
3.Set the ohmmeter to the R x 1 scale.
4.Touch the ohmmeter test leads to heater terminals 1 and 2. The meter should indi- cate as follows:
962 Ω @ 68°F (20°C)
1000 Ω @ 86°F (30°C)
1200 Ω @ 140°F (60°C)
1 2
WATER FILL VALVES
Refer to page
1.Unplug dishwasher or disconnect power.
2.Disconnect the wire connectors from the water fill valve solenoid terminals.
3.Set the ohmmeter to the R x 1 scale.
4.Touch the ohmmeter test leads to the up- per and lower water fill valve solenoid
terminals. The meter should indicate be- tween 65 and 75 Ω.
Upper
Solenoid
Terminals
Lower