Frymaster FBRA18 Series manual Semi-Annual Checks and Services, Clean Combustion Air Blower

Page 19

2.Press the Temperature Display switch once to display the temperature of the water as sensed by the temperature probe. Press the Temperature Display switch again to display the set point. The displayed water temperature should be within ±10°F (5°C) of the setpoint and the temperature shown on the thermometer or pyrometer should be within ± 5ºF (2ºC) of the displayed water temperature. If either set of readings is outside its range, contact a Factory Authorized Service Center for assistance.

4.3Semi-Annual Checks and Services

Clean Combustion Air Blower

1.Unplug the rethermalizer.

2.There are 4 wires (2 orange, 1 white, and 1 black) running from the motor. Remove the wire nuts and disconnect these wires from the rethermalizer wiring harness, marking each to ensure proper reconnection.

3.Remove the 4 nuts and bolts securing the blower to its mounting bracket and remove the blower from beneath the rethermalizer.

4.Remove the 3 motor flange nuts from the side of the blower housing and remove the motor and blower wheel from the housing.

5.Wrap the motor with plastic wrap to prevent water from entering it. Spray degreasing detergent on the blower wheel and blower housing. Wait 5 minutes, then rinse under hot water, being careful not to get water into the motor. Dry with a clean cloth.

6.Reverse steps 1-5 to reinstall the blower.

7.Light the rethermalizer in accordance with the procedure described in Chapter 3, Section 3.1.

8.After the burners have been lit for at least 90 seconds, observe the flames through the burner viewing ports. The air/gas mixture is properly adjusted when the burner manifold gas pressure is in accordance with the table on page 4-3 and the burners display a bright orange-red glow. If a blue flame is observed, or if there are dark spots on a burner face, the air/gas mix requires ad- justment.

On the side of the blower housing opposite the motor is a plate with one or two locking nuts. Loosen the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to open or close the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in position and retighten the nut(s).

Clean Gas Valve Vent Tube

1.Set the rethermalizer power switch and the gas valve to the OFF position.

2.Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for ease in removal.

4-2

Image 19
Contents Hour Service Hotline Canada Page FBR18 & FBRA18 Series GAS Rethermalizers Table of Contents Parts List Safety Information Parts Ordering and Service InformationEquipment Description Installation, Operating, and Service PersonnelDefinitions What to do if your equipment arrives damaged Shipping Damage Claim ProcedureGeneral Installation Requirements Caster/Leg Installation Incoming Gas Pressures Connecting to the Gas Supply Converting to Another Gas Type FBR18/FBRA18 Digital Controller IntroductionOperating the FBR18/FBRA18 Timers Boiling-Out the Cookpot Shutting the Rethermalizer Down Quarterly Checks and Services Daily Checks and ServicesClean Combustion Air Blower Semi-Annual Checks and ServicesCheck Burner Manifold Pressure Burner Manifold Gas Pressures Introduction To FBRA18 units only Troubleshooting GuidesProblem Yes Has the correct setpoint Yes Replacing the Controller or Controller Wiring Harness Functional Description FBR18 & FBRA18 Series GAS Rethermalizers Service ProceduresController and Mechanical Timers Temperature Probe Checking the Burner Manifold Gas Pressure Cleaning the Gas Valve Vent TubeMeasuring Flame Current Replacing the Interface Board Replacing the Temperature ProbeReplacing an Ignition Module Replacing an Ignitor AssemblyReplacing the Combustion Air Blower Replacing a Burner AssemblyReplacing the Gas Valve Replacing the Cookpot Troubleshooting and Problem IsolationIgnition Failures Improper Burner Functioning Incoming Gas PressuresPage Improper Temperature Control Troubleshooting the Gas Valve Unit is Connected to Troubleshooting the 24 VAC Circuit in FBR18 Units24 VAC Circuit in FBR18 Units Is Power Troubleshooting the 24 VAC Circuit in FBRA18 UnitsIs 24VAC Present on COM No terminal of latch Relay? Harness Is J1 pin 24VAC Circuit in FBRA18 Units Troubleshooting the Temperature Probe Probe Resistance Chart 8050417D Wiring Diagram for FBR18 UnitsFBRA18 Units Burner System Components FBR18 & FBRA18 Series GAS Rethermalizers Parts ListCabinetry and Associated Components Control Box Assembly and Associated Parts, FBR18/ FBRA18 Controller and Component Box Assemblies Cooking Timer Control Panel Components Cookpot, FBR18 Cookpot, FBRA18 Gas Supply Components Plumbing Components Page Service Hotline