Frymaster FBRA18 Series manual Has the correct setpoint

Page 25

WATER NOT HEATING.

AUTOFILL (IF INSTALLED)

WORKED PROPERLY.

Press the Temperature Check button twice to display setpoint.

Has the correct setpoint

No

been programmed?

 

Yes

 

Did burners

No

light?

 

Yes

 

Did water reach

No

setpoint temperature?

 

Yes

 

Problem resolved.

Program setpoint in

accordance with instructions

in Chapter 3.

Refer to troubleshooting guide "BURNERS DO NOT LIGHT".

Insert a good grade thermometer into

cookpot with tip near temperature probe and wait two minutes. Press the Temperature Check button once to display cookpot temperature.

Is temperature

 

There is a problem in

displayed reasonably

No

temperature probe

close to thermometer

 

 

circuit. Call FASC.

reading?

 

 

 

Yes

 

 

Temperature control

 

 

features are working properly.

 

 

If water still fails to reach

 

 

setpoint, call FASC.

 

 

5-4

Image 25
Contents Hour Service Hotline Canada Page FBR18 & FBRA18 Series GAS Rethermalizers Table of Contents Parts List Safety Information Parts Ordering and Service InformationEquipment Description Installation, Operating, and Service PersonnelDefinitions What to do if your equipment arrives damaged Shipping Damage Claim ProcedureGeneral Installation Requirements Caster/Leg Installation Incoming Gas Pressures Connecting to the Gas Supply Converting to Another Gas Type FBR18/FBRA18 Digital Controller IntroductionOperating the FBR18/FBRA18 Timers Boiling-Out the Cookpot Shutting the Rethermalizer Down Quarterly Checks and Services Daily Checks and ServicesClean Combustion Air Blower Semi-Annual Checks and ServicesCheck Burner Manifold Pressure Burner Manifold Gas Pressures Introduction To FBRA18 units only Troubleshooting GuidesProblem Yes Has the correct setpoint Yes Replacing the Controller or Controller Wiring Harness Functional Description FBR18 & FBRA18 Series GAS Rethermalizers Service ProceduresController and Mechanical Timers Temperature Probe Checking the Burner Manifold Gas Pressure Cleaning the Gas Valve Vent TubeMeasuring Flame Current Replacing the Interface Board Replacing the Temperature ProbeReplacing an Ignition Module Replacing an Ignitor AssemblyReplacing the Combustion Air Blower Replacing a Burner AssemblyReplacing the Gas Valve Replacing the Cookpot Troubleshooting and Problem IsolationIgnition Failures Improper Burner Functioning Incoming Gas PressuresPage Improper Temperature Control Troubleshooting the Gas Valve Unit is Connected to Troubleshooting the 24 VAC Circuit in FBR18 Units24 VAC Circuit in FBR18 Units Is Power Troubleshooting the 24 VAC Circuit in FBRA18 UnitsIs 24VAC Present on COM No terminal of latch Relay? Harness Is J1 pin 24VAC Circuit in FBRA18 Units Troubleshooting the Temperature Probe Probe Resistance Chart 8050417D Wiring Diagram for FBR18 UnitsFBRA18 Units Burner System Components FBR18 & FBRA18 Series GAS Rethermalizers Parts ListCabinetry and Associated Components Control Box Assembly and Associated Parts, FBR18/ FBRA18 Controller and Component Box Assemblies Cooking Timer Control Panel Components Cookpot, FBR18 Cookpot, FBRA18 Gas Supply Components Plumbing Components Page Service Hotline