5.2Troubleshooting Guides
NOTE: This guide applies
to FBRA18 units only.
Controller is not functioning.
Probable causes are failed 12V
transformer, failed interface board, or failed controller.
Probable causes are a failed
interface board or
failed/loose
sensor wiring.
Problem resolved.
Call FASC.
COOKPOT DID NOT FILL
WHEN UNIT WAS TURNED ON.
WATER SUPPLY TO UNIT
VERIFIED TO BE ON.
Did anything appear
No in controller display when unit was turned on?
Yes
Open control panel by
removing screws in each upper corner.
Is WATER
LED on interface board Yes illuminated?
No
Use bottlebrush to clean water level sensors.
No | Did LED |
|
| illuminate? |
|
| Yes |
|
Yes | Did unit begin | No |
| to fill? |
|
Probable causes are a failed
water solenoid or a failed
interface board.