Frymaster FBRA18 Series manual Introduction, FBR18/FBRA18 Digital Controller

Page 14

FBR18 & FBRA18 SERIES GAS RETHERMALIZERS

CHAPTER 3: OPERATING INSTRUCTIONS

3.1Introduction

Mechanically, the FBR18 and FBRA18 rethermalizers are virtually identical, the only difference being that the FBRA18 units have an automatic filling (AutoFill) feature. Both units use the same digital temperature controller and mechanical timers.

In operation, a setpoint is programmed into the controller which then regulates burner firing to maintain the water in the cookpot at the desired temperature. Six individual color-coded mechani- cal timers allow different types or quantities of product to be rethermalized simultaneously. The timers are equipped with an alarm to notify the operator that rethermalizing is complete. The prod- uct baskets have color-coded handles that correspond to the timers to eliminate confusion.

3.2FBR18/FBRA18 Digital Controller

 

 

 

 

Celsius or

 

Power

Digital

 

Fahrenheit

 

Switch

Display

 

Display Switch

 

 

9 . 9

9

9

C

 

 

 

 

Frymaster

 

 

 

 

 

Temperature

Setpoint

 

Melt

Heating

or Setpoint

Adjustment

Cycle

Mode

Display Switch

Arrows

 

Switch

Indicator

OPERATING THE FBR18/FBRA18 DIGITAL CONTROLLER

WARNING

Ensure the cookpot is filled with water before turning the controller on. “Dry firing” will cause damage to the cookpot!

1.Turn the controller on by pressing the Power switch. The controller software version num- ber will display for 4 seconds in the digital display then change to the last programmed setpoint temperature.

3-1

Image 14
Contents Hour Service Hotline Canada Page FBR18 & FBRA18 Series GAS Rethermalizers Table of Contents Parts List Parts Ordering and Service Information Safety InformationDefinitions Installation, Operating, and Service PersonnelEquipment Description Shipping Damage Claim Procedure What to do if your equipment arrives damagedGeneral Installation Requirements Caster/Leg Installation Incoming Gas Pressures Connecting to the Gas Supply Converting to Another Gas Type Introduction FBR18/FBRA18 Digital ControllerOperating the FBR18/FBRA18 Timers Boiling-Out the Cookpot Shutting the Rethermalizer Down Daily Checks and Services Quarterly Checks and ServicesSemi-Annual Checks and Services Clean Combustion Air BlowerCheck Burner Manifold Pressure Burner Manifold Gas Pressures Introduction Troubleshooting Guides To FBRA18 units onlyProblem Yes Has the correct setpoint Yes Replacing the Controller or Controller Wiring Harness FBR18 & FBRA18 Series GAS Rethermalizers Service Procedures Functional DescriptionController and Mechanical Timers Temperature Probe Measuring Flame Current Cleaning the Gas Valve Vent TubeChecking the Burner Manifold Gas Pressure Replacing the Temperature Probe Replacing the Interface BoardReplacing an Ignitor Assembly Replacing an Ignition ModuleReplacing the Gas Valve Replacing a Burner AssemblyReplacing the Combustion Air Blower Troubleshooting and Problem Isolation Replacing the CookpotIgnition Failures Incoming Gas Pressures Improper Burner FunctioningPage Improper Temperature Control Troubleshooting the Gas Valve Troubleshooting the 24 VAC Circuit in FBR18 Units Unit is Connected to24 VAC Circuit in FBR18 Units Troubleshooting the 24 VAC Circuit in FBRA18 Units Is PowerIs 24VAC Present on COM No terminal of latch Relay? Harness Is J1 pin 24VAC Circuit in FBRA18 Units Troubleshooting the Temperature Probe Probe Resistance Chart Wiring Diagram for FBR18 Units 8050417DFBRA18 Units FBR18 & FBRA18 Series GAS Rethermalizers Parts List Burner System ComponentsCabinetry and Associated Components Control Box Assembly and Associated Parts, FBR18/ FBRA18 Controller and Component Box Assemblies Cooking Timer Control Panel Components Cookpot, FBR18 Cookpot, FBRA18 Gas Supply Components Plumbing Components Page Service Hotline