Frymaster FBRA18 Series manual Check Burner Manifold Pressure

Page 20

Vent Tube

3.Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any obstruction.

4.Remove the wire, then blow through the tube to ensure it is clear.

5.Reinstall tube and bend so that the opening is pointing downward.

Check Burner Manifold Pressure

WARNING

Frymaster recommends that this task be performed by the local gas company or an

authorized service technician only.

1.Ensure that the gas valve knob is in the OFF position.

2.Remove the pressure tap plug from the gas valve assembly and attach the fitting for a gas pressure-measuring device to the tap.

Pressure

Tap Plug

Regulator Cap

3.Place the gas valve in the ON position. When the burner lights and continues below.

Place the controller power switch in the ON position. to burn, compare the indicated pressure to the table

4-3

Image 20
Contents Hour Service Hotline Canada Page FBR18 & FBRA18 Series GAS Rethermalizers Table of Contents Parts List Parts Ordering and Service Information Safety InformationDefinitions Installation, Operating, and Service PersonnelEquipment Description Shipping Damage Claim Procedure What to do if your equipment arrives damagedGeneral Installation Requirements Caster/Leg Installation Incoming Gas Pressures Connecting to the Gas Supply Converting to Another Gas Type Introduction FBR18/FBRA18 Digital ControllerOperating the FBR18/FBRA18 Timers Boiling-Out the Cookpot Shutting the Rethermalizer Down Daily Checks and Services Quarterly Checks and ServicesSemi-Annual Checks and Services Clean Combustion Air BlowerCheck Burner Manifold Pressure Burner Manifold Gas Pressures Introduction Troubleshooting Guides To FBRA18 units onlyProblem Yes Has the correct setpoint Yes Replacing the Controller or Controller Wiring Harness FBR18 & FBRA18 Series GAS Rethermalizers Service Procedures Functional DescriptionController and Mechanical Timers Temperature Probe Measuring Flame Current Cleaning the Gas Valve Vent TubeChecking the Burner Manifold Gas Pressure Replacing the Temperature Probe Replacing the Interface BoardReplacing an Ignitor Assembly Replacing an Ignition ModuleReplacing the Gas Valve Replacing a Burner AssemblyReplacing the Combustion Air Blower Troubleshooting and Problem Isolation Replacing the CookpotIgnition Failures Incoming Gas Pressures Improper Burner FunctioningPage Improper Temperature Control Troubleshooting the Gas Valve Troubleshooting the 24 VAC Circuit in FBR18 Units Unit is Connected to24 VAC Circuit in FBR18 Units Troubleshooting the 24 VAC Circuit in FBRA18 Units Is PowerIs 24VAC Present on COM No terminal of latch Relay? Harness Is J1 pin 24VAC Circuit in FBRA18 Units Troubleshooting the Temperature Probe Probe Resistance Chart Wiring Diagram for FBR18 Units 8050417DFBRA18 Units FBR18 & FBRA18 Series GAS Rethermalizers Parts List Burner System ComponentsCabinetry and Associated Components Control Box Assembly and Associated Parts, FBR18/ FBRA18 Controller and Component Box Assemblies Cooking Timer Control Panel Components Cookpot, FBR18 Cookpot, FBRA18 Gas Supply Components Plumbing Components Page Service Hotline