the unit exceeds that temperature, the burner will stay on until the setpoint is reached. Check the reading when the burner has been on continuously for at least one minute.
6.6Replacing Components
6.6.1 Replacing the Controller or Controller Wiring Harness
Refer to Chapter 5, Section 5.3 for this procedure.
6.6.2 Replacing the Temperature Probe
1.Unplug the rethermalizer and drain the cookpot.
2.Remove the screws from the upper corners of the timer panel and swing the panel open from the top, allowing it to rest on its hinge tabs. Cut the probe leads off at the rear of the probe. NOTE: Once the probe leads have been cut, the probe cannot be reused. Work the Tinnerman retaining clip rearward off the probe.
3.Remove the two screws securing the probe cover to the probe block and remove the cover. Slip the failed probe out of the block from the cookpot side and replace with a new probe. Carefully remove the Tinnerman retaining clip from the replacement probe to allow the leads and short end of the probe to be inserted through the probe block from cookpot side. When the replacement probe has been inserted, work the retaining clip onto the probe until the probe is held securely in place. Reinstall the probe cover and timer panel.
4.Remove the screws from the upper corners of the control panel and swing the panel open from the top, allowing it to rest on its hinge tabs. Remove the two upper screws securing the compo- nent box to the rethermalizer. Rotate the box forward and outward to expose the
5.Unplug the
6.Reattach the
6.6.3 Replacing the Interface Board
1.Unplug the rethermalizer and drain the cookpot.
2.Remove the screws from the upper corners of the control panel and swing the panel open from the top, allowing it to rest on its hinge tabs.
3.Detach the grounding wire from the controller, unplug the