6.8.1 Troubleshooting the Gas Valve
MAIN GAS SUPPLY
VALVE VERIFIED TO BE
OPEN AND EQUIPMENT GAS
VALVE IN ON POSITION.
Is there 24VAC
on gas valve main coil (PV No terminal)?
Yes
What gas is the unit configured for?
NOTE: All voltage measurements must be made within 4 seconds of unit calling for heat. If unit does not fire within 4 seconds, ignition modules will lock out and controller must be turned off then back on to reset.
Problem is with
24VAC circuit. Refer to
Troubleshooting the
24VAC Circuit.
Natual Gas | LP (Propane) | |
Gas | ||
|
Is incoming |
| Problem is with gas |
| Is incoming | |
gas pressure | No | No | gas pressure | ||
W.C. |
| supply to fryer. |
| W.C. | |
kPa)? |
|
|
| kPa)? | |
Yes |
|
|
| Yes | |
Is burner manifold |
| Adjust pressure to |
| Is burner manifold | |
No | specification. If gas valve | No | |||
gas pressure 3.5" W.C. | gas pressure 8.25" W.C. | ||||
| will not adjust, replace gas |
| |||
(0.8 kPa)? |
|
| (2.5 kPa)? | ||
| valve. |
| |||
|
|
|
| ||
Yes |
|
|
| Yes | |
Is gas valve vent tube | Yes | Clear obstruction. | Yes | Is gas Valve vent tube | |
obstructed? |
|
| obstructed? | ||
|
|
| |||
No |
|
|
| No | |
|
| Problem is not with |
|
| |
|
| gas valve. |
|
|