Frymaster FBRA18 Series manual Wiring Diagram for FBR18 Units, 8050417D

Page 50

6.9Wiring Diagram for FBR18 Units

VALVE

GAS

HIGH TEMP. WIRE

NOTE: FLAME SENSOR WIRE MUST BE CONNECTED TO THE SAME IGNITOR AS ITS MATCHING HIGH VOLTAGE LEAD.

IGNITER

IGNITER

101C

23C

SAFETYDRAIN SWITCH

NO

 

 

 

 

36C

 

 

 

 

CABLE

VOLTAGE HIGH

C

NO

(ORN)(ORN)

C

NC

 

 

 

 

(ORN)

(ORN)

 

 

 

12C

 

 

 

 

13C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NC

CENT. SWITCH

 

 

BLOWER

(WHT)

(BLK)

111C

2C

8050417D

111C

10C

9C

49C

8

4

7

3

6

2

5

1

 

11C

WHITE

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

GREEN

12 LOAD

LINE 120

RT.

 

 

MODULE

MODULE

SPARK

IGNITION

(BURNER)

25V

 

GND

 

 

 

VALVE

 

 

ALARM

(GND)

 

25V

24 LOAD

LINE 120

 

51C

 

LT.

 

 

MODULE

MODULE

SPARK

IGNITION

(BURNER)

25V

 

GND

 

 

 

VALVE

 

 

ALARM

(GND)

 

25V

120 VAC CORDSET

 

 

 

 

7C

 

 

12C

14C

 

19C

18C

 

 

 

9

 

8

 

7

 

 

6

5

4

 

 

 

 

42C

 

 

53C

60C

16C

 

 

GND

 

10

11

 

12

 

GND

V1D PWR

ALRM

V1S

 

 

 

 

 

7

8

 

9

 

 

 

 

 

 

 

 

 

 

1 4

2 5

 

3 6

 

 

 

GND

 

 

 

 

 

 

 

**

 

J3

 

 

 

 

55C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 10

8 11

 

9 12

 

 

 

GND

 

 

 

SOUND

1 2

3

1 4

2 5

 

3 6

 

22CGND

21C

 

V2S

 

17C

GND

 

J1

SA

 

 

 

 

 

 

 

 

 

V2D PWR AD

 

 

 

 

CONTROLLER

 

 

 

 

 

LIGHT TROUBLE

 

 

 

 

TEMP. PROBE

 

4C

 

 

 

 

 

 

 

 

 

 

 

 

 

43C

 

 

44C

 

 

3

2

1

 

 

 

J2

 

 

 

 

2C

 

 

12

 

 

 

11

5C

 

 

10

 

 

 

9

56C

 

 

8

8C

 

 

7

 

 

 

6

 

 

 

5

 

 

 

4

 

 

 

3

3C

 

 

2

 

 

 

1

1C

 

 

J3

 

6-23

Image 50
Contents Hour Service Hotline Canada Page FBR18 & FBRA18 Series GAS Rethermalizers Table of Contents Parts List Parts Ordering and Service Information Safety InformationDefinitions Installation, Operating, and Service PersonnelEquipment Description Shipping Damage Claim Procedure What to do if your equipment arrives damagedGeneral Installation Requirements Caster/Leg Installation Incoming Gas Pressures Connecting to the Gas Supply Converting to Another Gas Type Introduction FBR18/FBRA18 Digital ControllerOperating the FBR18/FBRA18 Timers Boiling-Out the Cookpot Shutting the Rethermalizer Down Daily Checks and Services Quarterly Checks and ServicesSemi-Annual Checks and Services Clean Combustion Air BlowerCheck Burner Manifold Pressure Burner Manifold Gas Pressures Introduction Troubleshooting Guides To FBRA18 units onlyProblem Yes Has the correct setpoint Yes Replacing the Controller or Controller Wiring Harness FBR18 & FBRA18 Series GAS Rethermalizers Service Procedures Functional DescriptionController and Mechanical Timers Temperature Probe Measuring Flame Current Cleaning the Gas Valve Vent TubeChecking the Burner Manifold Gas Pressure Replacing the Temperature Probe Replacing the Interface BoardReplacing an Ignitor Assembly Replacing an Ignition ModuleReplacing the Gas Valve Replacing a Burner AssemblyReplacing the Combustion Air Blower Troubleshooting and Problem Isolation Replacing the CookpotIgnition Failures Incoming Gas Pressures Improper Burner FunctioningPage Improper Temperature Control Troubleshooting the Gas Valve Troubleshooting the 24 VAC Circuit in FBR18 Units Unit is Connected to24 VAC Circuit in FBR18 Units Troubleshooting the 24 VAC Circuit in FBRA18 Units Is PowerIs 24VAC Present on COM No terminal of latch Relay? Harness Is J1 pin 24VAC Circuit in FBRA18 Units Troubleshooting the Temperature Probe Probe Resistance Chart Wiring Diagram for FBR18 Units 8050417DFBRA18 Units FBR18 & FBRA18 Series GAS Rethermalizers Parts List Burner System ComponentsCabinetry and Associated Components Control Box Assembly and Associated Parts, FBR18/ FBRA18 Controller and Component Box Assemblies Cooking Timer Control Panel Components Cookpot, FBR18 Cookpot, FBRA18 Gas Supply Components Plumbing Components Page Service Hotline