Frymaster FBRA18 Series manual Problem Yes

Page 24

NOTE: This guide applies

to FBRA18 units only.

WATER DID NOT SHUT OFF WHEN COOKPOT WAS FULL.

Use bottlebrush to clean

water level sensors.

Problem

Yes

Did water

resolved.

 

stop?

 

 

No

Add 1/8 cup of salt to water in cookpot and stir.

Mineral content of water is

 

 

insufficient for water sensor to

Yes

Did water

detect it. Whenever cookpot is

 

stop?

refilled, add 1/8 cup of salt.

 

 

 

 

No

Remove the cover over the water sensors and thoroughly clean the sensors with a Scotchbrite or similar pad.

If water still does not stop,

probable cause is

failed/loose high water

sensor wiring.

Open control panel by

removing screws in each

upper corner.

Yes

Is WATER

No

LED on interface board

 

 

 

illuminated?

 

Call FASC.

Probable cause is failed

water solenoid.

5-3

Image 24
Contents Hour Service Hotline Canada Page FBR18 & FBRA18 Series GAS Rethermalizers Table of Contents Parts List Parts Ordering and Service Information Safety InformationInstallation, Operating, and Service Personnel Equipment DescriptionDefinitions Shipping Damage Claim Procedure What to do if your equipment arrives damagedGeneral Installation Requirements Caster/Leg Installation Incoming Gas Pressures Connecting to the Gas Supply Converting to Another Gas Type Introduction FBR18/FBRA18 Digital ControllerOperating the FBR18/FBRA18 Timers Boiling-Out the Cookpot Shutting the Rethermalizer Down Daily Checks and Services Quarterly Checks and ServicesSemi-Annual Checks and Services Clean Combustion Air BlowerCheck Burner Manifold Pressure Burner Manifold Gas Pressures Introduction Troubleshooting Guides To FBRA18 units onlyProblem Yes Has the correct setpoint Yes Replacing the Controller or Controller Wiring Harness FBR18 & FBRA18 Series GAS Rethermalizers Service Procedures Functional DescriptionController and Mechanical Timers Temperature Probe Cleaning the Gas Valve Vent Tube Checking the Burner Manifold Gas PressureMeasuring Flame Current Replacing the Temperature Probe Replacing the Interface BoardReplacing an Ignitor Assembly Replacing an Ignition ModuleReplacing a Burner Assembly Replacing the Combustion Air BlowerReplacing the Gas Valve Troubleshooting and Problem Isolation Replacing the CookpotIgnition Failures Incoming Gas Pressures Improper Burner FunctioningPage Improper Temperature Control Troubleshooting the Gas Valve Troubleshooting the 24 VAC Circuit in FBR18 Units Unit is Connected to24 VAC Circuit in FBR18 Units Troubleshooting the 24 VAC Circuit in FBRA18 Units Is PowerIs 24VAC Present on COM No terminal of latch Relay? Harness Is J1 pin 24VAC Circuit in FBRA18 Units Troubleshooting the Temperature Probe Probe Resistance Chart Wiring Diagram for FBR18 Units 8050417DFBRA18 Units FBR18 & FBRA18 Series GAS Rethermalizers Parts List Burner System ComponentsCabinetry and Associated Components Control Box Assembly and Associated Parts, FBR18/ FBRA18 Controller and Component Box Assemblies Cooking Timer Control Panel Components Cookpot, FBR18 Cookpot, FBRA18 Gas Supply Components Plumbing Components Page Service Hotline