Frymaster BIGLA30 warranty Computer Information for the M3000 Computers

Page 7

DANGER

DANGER boxes contain information about actions or conditions that may cause or result in injury to personnel, and which may cause damage to your system and/or cause your system to malfunction.

Your fryer is equipped with automatic safety features:

1.High-temperature detection shuts off gas to the burner assembly should the controlling thermostat fail.

2.A safety circuit on units with filter systems prevents burner ignition with the drain valve open.

1.3Computer Information for the M3000 Computers

FCC COMPLIANCE

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. While this device is a verified Class A device, it has been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harmful interference when the equipment is op- erated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio com- munications.

Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

The user is cautioned that any changes or modifications not expressly approved by the party responsible for com- pliance could void the user's authority to operate the equipment.

If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions.

The user may find the following booklet prepared by the Federal Communications Commission helpful: "How to Identify and Resolve Radio-TV Interference Problems". This booklet is available from the U.S. Government Print- ing Office, Washington, DC 20402, Stock No. 004-000-00345-4.

1.4European Community (CE) Specific Information

The European Community (CE) has established certain specific standards regarding equipment of this type. Whenever a conflict exists between CE and non-CE standards, the information or instructions concerned are identified by means of shadowed boxes.

1.5Installation, Operating, and Service Personnel

Operating information for Frymaster equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.6. All installation and service on Frymaster equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel, as defined in Section 1.6.

1-2

Image 7
Contents Manufactured Canada Page LOV GAS Warranty Statement Parts Return General Safety InformationComputer Information for the M3000 Computers Installation, Operating, and Service PersonnelEuropean Community CE Specific Information Qualified Service Personnel Qualified Installation PersonnelQualified AND/OR Authorized Operating Personnel Retain and Store this Manual in a Safe Place for Future USE Clearance and Ventilation General Installation RequirementsElectrical Grounding Requirements National Code RequirementsCaster Installation Non-CE Standard For Incoming Gas Pressures Gas Connection Pipe Sizes CE Standard Single Dual Gas Vat Converting to Another Gas TypeCE GAS Conversion Instructions Non-CE Gas Conversion KitsNon-CE Gas Conversion Kits for Australia CE Gas Conversion Kits for Units with Gas ValveAfter Fryers are Positioned at the Frying Station BIGLA30 Series GEN II LOV GAS Fryer Operating Instructions Typical Configuration BIGLA330 ShownPage Lighting the Fryer Press the computer ON/OFF switch to the OFF positionOperation ShutdownChanging the JIB Low Oil Volume Automatic RefillInstall the JIB Prepare the System for UseFront of the fryer off see Figure M3000 General Information FR FriesBasic Operation Cooking with Multi-Product Display Cooking with Dedicated Display Changing from Breakfast Setup to Lunch Changing from Lunch Setup to Breakfast Cook Channel and Selection Buttons Filter, Temperature and Info ButtonsM3000 Button Description and Functions Navigation ButtonsDraining, Refilling, and Disposing of Oil M3000 Menu Summary Tree1234 Fryer Setup Mode Programming24hR Escape Menu Items 10 M3000 Common TasksFull Prod Adding New Product Items to the Menu Product SelectionSelection ProductCook ID Disable Product selection prompt Storing Menu Items in Product ButtonsTo Level 1 program changing to the Product selection Disposal for Non-Bulk Oil Systems Draining and Refilling Vats, and Disposing of OilRefilling JIB Oil Systems Draining and Disposing Oil using Bulk Oil SystemsPage Refilling the Vat from Bulk Oil Systems after Disposal Accessing the Filter MenuDrain to Pan Yes no Fill Vat from Drain PanFill Vat from Bulk Pan to Waste Programming Level OneAIF Clock Selection display Deep Clean Mode BOIL-OUTEMPTY? and Yes no PANPage HIGH-LIMIT Test Mode Comp Programming Level TwoLevel 2 Program Product Comp ModePassword Setup Mode LOG ModeAlert Tone Mode Filter After Filter Time Info ModeFull VAT Configuration Filter Stats ModeSplit VAT Configuration DAY wed, Date 03/20/07 Current day and date Review Usage ModeFull / Split VAT Configuration Last Load Mode4321 Page Introduction BIGLA30 Series GEN II LOV GAS Fryer Filtration InstructionsDo not USE Filter Powder with the PAD Auto Demand Filtration DRAINING, Washing and Filling during the processPage Clogged Drain Error FIXED? YES no is displayed Filter Error FlowchartSystem Error Normal Operation ResumesClogged Drain or Oil Sensor Fail Flowchart Filter Busy Page Page Clean Fryer Cabinet Inside and Out Daily Fryer Preventive Maintenance Checks and ServiceDaily Checks and Service Inspect Fryer and Accessories for DamageClean Filter Pan, Detachable Parts and Accessories Weekly Checks and Service 6.3.1 Clean Behind FryersCleaning the Frypot Quarterly Deep Clean Boiling Out the FrypotCheck M3000 Computer Set Point Accuracy BI-WEEKLY Checks and ServiceQuarterly Checks and Service Clean Combustion Air Blower AssemblyLeft Viewing PortRight Port is Behind Motor Fryer Clean Oil Level SensorReplace the O-RINGS Annual/Periodic System InspectionBuilt-In Filtration System BIGLA30 Series GEN II LOV GAS Fryer Operator Troubleshooting Change Filter Service Auto Top Off Problems Probable Causes Corrective Action Explanation ProblemError Drain Valve not Closed Used oil to a JIB Bulk Oil SystemsService Hotline