HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
Interface Boards (cont.)
FREQUENTLY USED TEST POINTS FOR HIGH EFFICIENCY DECATHLON (HD) FRYERS
Test | Meter Setting | Pins | Test Results |
|
|
|
|
12VAC Power to Controller | 50 VAC Scale | 1 and 3 on J3 | |
|
|
|
|
12VDC Power to Right BL Relay | 50 VDC Scale | 4 on J2 and 5 on J2 | |
|
|
|
|
12VDC Power to Left BL Relay | 50 VDC Scale | 7 on J1 and 5 on J2 | |
|
|
|
|
24VAC Power to | 50 VAC Scale | 6 on J2 and GROUND | |
|
|
|
|
24VAC Power | 50 VAC Scale | 2 on J2 and GROUND | |
|
|
|
|
24VAC Power To 24VAC Gas Valve | 50 VAC Scale | 7 on J2 and GROUND | |
|
|
|
|
Probe Resistance* | R x 1000 Ohms | 10 and 11 on J2 | ** |
|
|
|
|
*Disconnect
**See Probe Resistance Chart at the end of this chapter.
| HIGH EFFICIENCY DECATHLON (HD) FRYER |
| LED DIAGNOSTIC LIGHTS |
| |
|
|
CMP | Indicates power from 12V transformer. |
24V | Indicates power from 24V transformer. |
HI | Indicates output (closed) from latch relay (K4). |
HT | Indicates output from heat relay (K3). |
AL | Indicates output (open) from latch relay (K4). |
The board contains two heat relays (K2 and K3), and two basket lift relays (K1 and K4). NOTE: On