HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1.9Troubleshooting Guides (cont.)
| C. | Gas valve is known to be good, but | D. | Inspect electronic sensor (while still in | |
|
| there is not 24 VAC (120VAC on |
| frypot) for damage. Replace if bent, | |
|
| systems so equipped) at the gas valve |
| dented, or cracked. Inspect leads for | |
|
| terminals. |
| fraying, burning, breaks, and/or kinks. | |
|
|
|
| If found, remove and replace | |
|
|
|
| thermostat(s). Remove leads from | |
No burner flame. |
|
|
| terminal block, allow oil to cool 15°F | |
|
|
| (8°C) below thermostat setting, and | ||
|
|
|
| check continuity. If continuity is not | |
|
|
|
| "0,” then thermostat has failed. | |
|
|
|
| Replace thermostat(s). | |
|
|
|
|
| |
| E. | Continuity from terminal block to gas | E. | Inspect wiring for breaks or shorts and | |
|
| valve electronic/operating thermostat |
| repair if necessary. | |
|
| wire is not "0." |
|
| |
|
|
|
|
| |
| A. | Incoming gas supply pressures are not | A. | Inspect gas supply to fryer. Repair | |
|
| within range [Natural- |
| and/or replace faulty components | |
|
|
| (defective supply | ||
Fluctuating or erratic |
| W.C. |
| incorrect piping size, etc.) | |
|
|
|
| ||
B. | Air in gas supply lines (new | B. | Allow unit to cycle on and off for | ||
lighting of burner flame. | |||||
|
| installation). |
| approximately 30 minutes to force air | |
|
|
|
| from gas manifold and lines. | |
|
|
|
|
| |
Electronic/operating | A. | Electronic/operating thermostat is out | A. | Calibrate electronic/operating | |
thermostat will not adjust |
| of calibration. |
| thermostat. Replace if calibration is | |
to correct temperature. |
|
|