Once the fryer has been positioned at the frying station, use a carpenter’s level placed across the top of the frypot to verify that the unit is level, both side-to-side and front-to-back.

To level fryers equipped with legs, the bottom of the legs can be screwed out up to one inch for leveling. Legs should also be adjusted so that the fryer(s) are at the proper height in the frying station.

For fryers equipped with casters, there are no built-in leveling devices. The floor where the fryers are installed must be level.

When the fryer is leveled in its final position, install the restraints provided with the unit to limit its movement so that it does not depend on or transmit stress to the electrical conduit or connection. Install the restraints in accordance with the provided instructions (see illustration below). If the restraints are disconnected for service or other reasons, they must be reconnected before the fryer is used.

DANGER

Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to electrical conduits or gas supply line. A restraint kit is provided with the fryer. If the restraint kit is missing contact your local Frymaster Factory Authorized Service Center (FASC) for part number 826-0900.

NOTE: If you need to relocate a fryer installed with legs, remove all weight from each leg before moving. If a leg becomes damaged, contact your service agent for immediate repair or replacement.

DANGER

Hot oil can cause severe burns. Avoid contact. Under all circumstances, oil must be removed from the fryer before attempting to move it to avoid oil spills, falls, and severe burns. This fryer may tip and cause personal injury if not secured in a stationary position.

1-8

Image 13
Contents Includes HD63/Red Robin and Common Cabinetry Hour Service HotlineMAY Page Computers FCC Table of Contents Page GAS Information Altitudes of 2000 feet or less Functional DescriptionElectronic Ignition Configuration Pilot System ConfigurationInterface Boards Control OptionsThermatron Board P/N Interface Boards Indicates power from 12V transformer Test Meter Setting Pins Test ResultsThermostats Accessing Fryers for ServicingRestraints Adjusting Burner Manifold Gas Pressure Cleaning the Gas Valve Vent Tube if applicableCalibrating the Thermatron Adjusting the Pilot FlameMain Pilot Trailing PilotReplacing the Computer Replacing Fryer ComponentsReplacing the Temperature Probe Computer-equipped Fryers Replacing the Temperature Probe Computer-equipped Fryers Probe cannot be repositioned Replacing the High-limit Thermostat Installing the New Temperature ProbeLocate the high-limit probe Capillary tube cannot be repositioned Figure B Replacing Rocker SwitchesReplacing Rocker Switches Replacing the Frypot Replacing the Pilot AssemblyRemoving the joiner strip Removing gas manifold shield Removing bolts arrows securing flue to frypot Nut Valve Boot Clamp Remove the drain valve nut and attached Hardware Cutting frypot seal prior to frypot removal Lifting frypot from fryer Ignition Failure Troubleshooting and Problem IsolationImproper Burner Function Electronic CircuitsImproper Burner Function Improper Temperature Control Improper Computer Function Improper Filtration Function Frypot Leakage Improper Basket Lift Function Bell-Crank Basket Lifts Problem Troubleshooting GuidesNot possible High Efficiency Decathlon, Thermatron with Constant Pilot Wiring DiagramsRight/left sides are the same Computer with Constant Pilot CM4-S Wiring Dean Oil Return Wiring Dean Oil Return Wiring, with Solenoid Probe Resistance Charts High Efficiency Decathlon HD Primary Components High Efficiency Decathlon Series GAS Fryers Parts ListSee Orifices, Section Decathlon HD50 Primary Components includes Scfhd unitsSee Drain Manifold Components, Section Decathlon HD50 Primary Components includes Scfhd units 823-4692 Decathlon HD60 Primary Components includes Scfhd unitsFlue Box Assembly also used on HD63 fryers Front, Flue Box Decathlon FPHD65 Primary Components Cabinet Upper Back Channel, Base 265 465 565Cabinet Lower Back Door Assembly, with Liner also used for HD63 fryers Natural Orifices OrificesPropane Orifices Accessories Control Panel Options, Joiner Strips, and AccessoriesControl Panels Joiner StripsOptional Components and Controllers HD/SCFHD50 SCFHD456 SCFHD60 BezelsInterface Boards High Efficiency Decathlon Series GAS Fryers Parts List Drain Valve Assembly, 1 1 ⁄ 2 with Microswitch Drain Valve Assembly, 1 1 ⁄ 2 without MicroswitchFlush Oil Drain Line Oil Return Manifold Components Oil Return Manifold Components Oil Return Manifold Components Oil Return and Oil Flush Components Oil Suction Assembly Microswitch Bracket Assembly, Oil ReturnSuction Manifold Assembly Oil Suction Start FittingDescription 106-7543 Filtration Components SCFHD60 and SCFHD63 Series FryersFiltration Components FPHD65 Series Fryers Basket Lift Components Basket Lift Components Trough, Holster, & Cover Components Fasteners Screws, Nuts, Bolts Service Hotline