Frymaster FPHD manual Locate the high-limit probe

Page 21

HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.7.4 Replacing the High-limit Thermostat (cont.)

6.Locate the high-limit probe inside the frypot. Remove the high-limit probe mounting hardware. Retain mounting hardware for installation of new temperature probe

Locate the high-limit probe.

7.Carefully pull high-limit capillary tube and bulb out of the frypot from the bottom.

Remove high-limit capillary tube and bulb from the bottom of the frypot.

1-16

Image 21
Contents Hour Service Hotline Includes HD63/Red Robin and Common CabinetryMAY Page Computers FCC Table of Contents Page GAS Information Altitudes of 2000 feet or less Functional DescriptionElectronic Ignition Configuration Pilot System ConfigurationInterface Boards Control OptionsThermatron Board P/N Interface Boards Indicates power from 12V transformer Test Meter Setting Pins Test ResultsThermostats Accessing Fryers for ServicingRestraints Adjusting Burner Manifold Gas Pressure Cleaning the Gas Valve Vent Tube if applicableCalibrating the Thermatron Adjusting the Pilot FlameMain Pilot Trailing PilotReplacing the Computer Replacing Fryer ComponentsReplacing the Temperature Probe Computer-equipped Fryers Replacing the Temperature Probe Computer-equipped Fryers Probe cannot be repositioned Replacing the High-limit Thermostat Installing the New Temperature ProbeLocate the high-limit probe Capillary tube cannot be repositioned Figure B Replacing Rocker SwitchesReplacing Rocker Switches Replacing the Frypot Replacing the Pilot AssemblyRemoving the joiner strip Removing gas manifold shield Removing bolts arrows securing flue to frypot Nut Valve Boot Clamp Remove the drain valve nut and attached Hardware Cutting frypot seal prior to frypot removal Lifting frypot from fryer Ignition Failure Troubleshooting and Problem IsolationImproper Burner Function Electronic CircuitsImproper Burner Function Improper Temperature Control Improper Computer Function Improper Filtration Function Frypot Leakage Improper Basket Lift Function Bell-Crank Basket Lifts Problem Troubleshooting GuidesNot possible Wiring Diagrams High Efficiency Decathlon, Thermatron with Constant PilotRight/left sides are the same Computer with Constant Pilot CM4-S Wiring Dean Oil Return Wiring Dean Oil Return Wiring, with Solenoid Probe Resistance Charts High Efficiency Decathlon HD Primary Components High Efficiency Decathlon Series GAS Fryers Parts ListDecathlon HD50 Primary Components includes Scfhd units See Orifices, SectionSee Drain Manifold Components, Section Decathlon HD50 Primary Components includes Scfhd units 823-4692 Decathlon HD60 Primary Components includes Scfhd unitsFlue Box Assembly also used on HD63 fryers Front, Flue Box Decathlon FPHD65 Primary Components Channel, Base 265 465 565 Cabinet Upper BackCabinet Lower Back Door Assembly, with Liner also used for HD63 fryers Orifices Natural OrificesPropane Orifices Accessories Control Panel Options, Joiner Strips, and AccessoriesControl Panels Joiner StripsOptional Components and Controllers HD/SCFHD50 SCFHD456 SCFHD60 BezelsInterface Boards High Efficiency Decathlon Series GAS Fryers Parts List Drain Valve Assembly, 1 1 ⁄ 2 without Microswitch Drain Valve Assembly, 1 1 ⁄ 2 with MicroswitchFlush Oil Drain Line Oil Return Manifold Components Oil Return Manifold Components Oil Return Manifold Components Oil Return and Oil Flush Components Oil Suction Assembly Microswitch Bracket Assembly, Oil ReturnSuction Manifold Assembly Oil Suction Start FittingDescription 106-7543 Filtration Components SCFHD60 and SCFHD63 Series FryersFiltration Components FPHD65 Series Fryers Basket Lift Components Basket Lift Components Trough, Holster, & Cover Components Fasteners Screws, Nuts, Bolts Service Hotline