Frymaster E4 manual Contactor, 24V

Page 59

2.5.2.1Left and Right Over the Filter Pan Contactor Box Configurations cont.

NOTES: Left and right contactor box assemblies are mirror images of one another. With the exception of the box itself, most components of a left-hand assembly are the same as those in the corresponding right-hand assembly and vice versa. The configurations illustrated show most possible components, but a particular configuration may not have all the components shown.

ITEM

PART #

COMPONENT

1

106-5488

Box Assembly, Left Contactor Standard (Over the Filter Pan)

 

106-7066

Box Assembly, Left Contactor Fryer ½ Half Fryer on Left

2823-5736 Box Assembly, Left Contactor EPRI (Over the Filter Pan)

3106-5489 Box Assembly, Right Contactor Standard (Over the Filter Pan)

106-6819 Box Assembly, Right Contactor Fryer ½ Half Fryer on Right

4823-5748 Box Assembly, Right Contactor EPRI (Over the Filter Pan)

5810-2554 Plug, Cord Cutout 1.125 Button

6807-1947 Plug, .875 Diameter Dome

7807-0064 Transformer, 480V/120V 150VA

8807-0922 Holder, Bus Fuse

*221-0482 Cover, Left Hand Standard Contactor Box

222-2072 Cover, Left Hand Fryer ½ Half fryer on Left

*222-0482 Cover, Right Hand Standard Contactor Box

 

220-1912

Cover, Right Hand Fryer ½ Half fryer on Right

9

807-0070

Terminal, Ground Lug

√ 10

807-1071

Contactor, 24V 30 Amp Mercury

√ 11

807-0884

Contactor, 24V 50

Amp Mercury

√ 12

807-2284

Contactor, 24V 50

Amp Mechanical (only in 14kW & 17kW units)

√ 13

807-2283

Contactor, 24V 63

Amp Mechanical (only in 22kW units)

√ 14

810-1202

Contactor, 24V 40

Amp Mechanical

15**

806-8674

Heatsink Assembly, DV Solid State Relay (See components below)

16**

806-8673

Heatsink Assembly, FV Solid State Relay (See components below)

 

 

Components of Items 15 and 16

√ 17

826-1562

Kit Relay, Solid State 40 Amp 280V with Heatsink

18807-2749 Heatsink, Solid State

19807-0037 Terminal, ¼-inch Push-on

20807-2278 Fuse, 20 Amp

21106-6204 Filter Assembly, EPRI (used in CE WYE-configured EPRI units only)

22807-0922 Holder, Bus Fuse

*221-0610 Bracket, Left Hand Contactor Box Mounting

*222-0610 Bracket, Right Hand Contactor Box Mounting

*807-0012 Relay, Tilt Switch 18 Amp 1/3 HP 24 V Coil

* Not illustrated.

** Full Vat has three relays 826-1562, Dual-Vat has six relays.

Recommended parts.

2-19

Image 59
Contents RE Series Electric Fryers Hour Service HotlinePage Electrical Power Specifications RE Series E4 Electric Fryers Table of Contents RE Series E4 Electric Fryers Replacing Component Box Components GeneralReplacing a Controller Removing the Control Panel Frame and Top Cap Assembly Replacing a High-Limit Thermostat Replacing a Temperature ProbePage Replacing a Heating Element Replacing Contactor Box Components Replacing a Frypot Page Right Sediment Particle Oil Flow Up for reverse Down for forward Disconnect flexlines indicated by the arrows Replacing the Filter Transformer or Filter Relay Basket Lift Service ProceduresBINDING/JAMMING Problems Motor and Gear Problems Diagnostic LED Legend Interface Board Diagnostic ChartProbe Resistance Chart Probe Resistance ChartWiring Diagrams Modular Basket Lift Wiring Diagram Modular Basket Lift Wiring Diagram Component Wiring Standard Fryers Component Wiring- Fryer and Half Tilt Switch Wiring Standard Fryer and half Component Wiring Fast Ready Fast Ready Computer Wiring Computer Harness Fast Ready Control Wiring Fast Ready Fryer and Half Wiring Contactor Delta ConfigurationContactor Box WYE Configuration Export Terminal Block Wiring Oil Disposal Wiring Series Full Vat Wiring13.12 Simplified RE14/17/22Simplified RE14/17/22 Series Dual Vat Wiring 13.14 Electric RE14/17/22 Series FULL-VAT ExportSimplified RE14/17/22 Series Dual Vat Wiring Export WYE Simplified RE14/17/22 Series Full Vat Wiring Epri Simplified RE14/17/22 Series Full Vat Wiring Epri Export WYE Accessories RE Series E4 Electric Fryers Parts ListBasket Lift Assembly and Associated Parts 106-1805SP Page Single Station Fryer CRS Use 230-0422 for Stainless Steel Bezel, One-Controlleruse 230-1953 for Fryer ½ Cabinets, Bases, Braces, and Associated Parts Component See next section for Drain Valves PART# Component Euro-Look Drain Tube Sections and Associated PartsSingle Footprint Full-Vat Drain Valve Assembly 106-6300 Full-Vat Drain Valve Assembly Fryer ½ Compression Washers Page Drain Valves and Assoc. Parts Units with Built-In Filtration Valve, 1.25-inch Non-Filter Full-Vat Drain Electronics and Wiring Components 2.5.1 Component Boxes Component Boxes Page 807-2283 Contactor, 24V Page 807-2283 Contactor Cover, RH Fuse Box Used on Single Station Fryers also Fuse BoxesTerminal Blocks Page Be replaced when Wire harnesses must2-30 for wire Heating Element Assemblies and Associated PartsElement Tube Assemblies Controllers Wiring Contactor Box Wiring Assemblies 12-Pin Dual-Vat C-1 Contactor Box Wiring Assemblies 12-Pin Full-Vat C-1 Contactor Box Wiring Assemblies 9-Pin Right Element Contactor Box Wiring Assemblies 6-Pin Left ElementMain Wiring Harnesses Full and Dual Vat Main Wiring Harnesses Fryer and ½ Component Box, Filter Pump and Basket Lift Wiring Harnesses Page Filtration System Components Roller Kit includes 4 rollers, 4 nuts and 4 lock washers √ Recommended parts Frypot Assemblies and Associated Parts Frypot Assembly does not include Item Typical Rear-Flush Oil Return Plumbing Oil Return System ComponentsOil Return System Components Oil Disposal Plumbing Oil Disposal Wand Wiring Connectors and Pin Connectors Fasteners Service Hotline
Related manuals
Manual 2 pages 51.67 Kb Manual 36 pages 37.47 Kb Manual 78 pages 9.63 Kb

E4 specifications

The Frymaster E4 is an advanced fryer that represents the cutting edge of commercial frying technology. Designed for efficiency and performance, it is favored by restaurants and fast-food chains looking to optimize their cooking processes while maintaining exceptional food quality.

One of the standout features of the Frymaster E4 is its programmable controls. With an intuitive digital interface, operators can easily adjust cooking temperatures, times, and even recipes with just a few taps. This level of precision ensures that food is consistently cooked to perfection every time, reducing waste and improving overall efficiency in the kitchen.

The E4 is equipped with high-performance burners that ensure rapid heating and recovery times. This means that cooking oil reaches the desired temperatures quickly, allowing for faster frying cycles. Thus, busy kitchens can meet high-demand periods without compromising quality or service speed. The fryer also features a high-efficiency oil filtration system that automatically removes contaminants and prolongs the life of the frying oil, resulting in a significant reduction in operating costs over time.

Another notable technology in the Frymaster E4 is its oil level management system, which actively monitors oil levels and alerts the operator when replenishment is necessary. This feature prevents overfilling or underfilling, both of which can negatively impact cooking performance and food quality.

Safety is also a top priority with the E4, as it incorporates features such as a built-in safety shut-off mechanism that activates if the temperature exceeds safe levels. Additionally, the fryer's robust construction minimizes the risks of spills and accidents in the kitchen, making it a reliable choice for high-traffic environments.

The Frymaster E4 also emphasizes energy efficiency, designed to meet stringent energy-saving standards without compromising performance. This is crucial in the current market, where energy costs can significantly impact overall profitability.

In conclusion, the Frymaster E4 offers an impressive combination of innovative technology, safety, and efficiency. Its programmable controls, high-performance frying capabilities, and advanced filtration and oil management systems make it an essential tool for any commercial kitchen aiming to enhance productivity and food quality. As the demands of the food industry continue to grow, the E4 stands out as a reliable partner for chefs looking to elevate their frying operations.