Frymaster 2424G, 1824G manual Adjusting the Pilot Flame where applicable

Page 13

24G SERIES FLATBOTTOM GAS FRYERS CHAPTER 1: SERVICE PROCEDURES

5.To adjust burner gas pressure, remove the cap from the gas valve regulator and adjust to correct pressure (arrows).

Pilot Ignition Valve (Line

Non-CE Electronic Ignition

CE Pilot Ignition Valve

Voltage)

Valve

 

6.Place the fryer power switch and the gas valve in the "OFF" position. Remove the pressure- measuring device fitting from the pressure tap hole and reinstall the pressure tap plug.

1.5 Adjusting the Pilot Flame (where applicable)

1.Remove the cap from the pilot adjustment screw hole on the gas valve.

2.Using a small, flat-tipped screwdriver, turn the pilot adjusting screw counterclockwise to increase length of flame or clockwise to decrease length of flame. Adjust to obtain a flame from 1 to 1-½ inches long.

3.Reinstall the pilot adjustment screw cap.

1.6 Calibrating the Thermatron Temperature Controller

1.Fill the frypot to the proper oil-level line with cooking oil/shortening. If solid shortening is used, ensure that the shortening is properly packed and melted in the frypot before proceeding.

2.Ensure the fryer ON/OFF switch is in the "OFF" position, and then light the pilot.

3.Place the fryer ON/OFF switch in the "ON" position. Set the Thermatron dial to 325°F (162°C).

4.Allow the oil/shortening to equilibrate at setpoint temperature. This is evident when the burners have cycled on and off several times.

1-7

Image 13
Contents 24G Series Flatbottom Gas Fryers Hour Service Hotline JunePage Computers Where Applicable FCC 24G Series Flatbottom Gas Fryers Table of Contents This page Intentionally Left Blank NON-CE Altitudes of 2000 feet or less Functional DescriptionCE only Altitudes of 2000 feet or less Electronic Ignition Configuration Pilot System ConfigurationControl Options No COM Relay Safety Components Accessing Fryers for ServicingAdjusting Burner Manifold Gas Pressure Cleaning the Gas Valve Vent Tube if applicableCalibrating the Thermatron Temperature Controller Adjusting the Pilot Flame where applicableLoosen two setscrews in dial arrows to recalibrate Replacing Fryer Components Remove/Replace Temperature Probe or High-Limit ThermostatTemperature probe High-limit Removing/Replacing Rocker Switches 24G Series Flatbottom GAS Fryers Service Procedures Removing/Replacing Blower Assembly or Air Prover Switch 24G Series Flatbottom GAS Fryers Service Procedures Frypot Baffle Inspection Replacing the FrypotFrypot/Firebox Removal/Replacement Procedure 24G Series Flatbottom GAS Fryers Service Procedures If the Firebox Requires Replacement Troubleshooting and Problem Isolation Ignition Failures Problems Related to the Electronic CircuitsImproper Burner Functioning 24G Series Flatbottom GAS Fryers Service Procedures Filtration Problems Improper Temperature ControlShortening to free gears Leakage Troubleshooting Guides To temperature quickly Power is present atTemperature Main Burner MalfunctionsLight Indication Probable Cause Corrective Action Indicator LightsWiring Diagrams 10.2 24G Series Single Fryers Non-CE with Boil-Out Switch 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 10.8 24G Series Single Fryers CE-Approved10.9 24GTI Oil Return/Filter System This page Intentionally Left Blank Blower Assembly, Combustion Air 24G Series Flatbottom GAS Fryers Parts ListBurner Manifold and Related Components Component Backs, Bases, Casters, Sides, Etc CabinetryNot illustrated Door Assemblies and Component Parts This page Intentionally Left Blank Flue Caps, Top Caps, and Related Components Not illustrated Control Panels, Wireways, and Related Components Component Under Fryer Filter UFF Components FiltrationComponent 24G Series Flatbottom GAS Fryers Caster, 2-inch Rigid use 810-2805 for 2-inch Swivel Caster This page Intentionally Left Blank 2 ND90 Built-In Filter System Components Line Parts Component Frypot, Drain and Oil-Return Components Component Drain Valve and Components Connectors 2-Pin Female 6-Pin Female 9-Pin Female Wiring Connectors, Pin Terminals and Power CordsService Hotline