1.7.6 Replacing the Frypot

Unit should be at room temperature, disconnected from gas and electrical service, and empty of oil or shortening prior to beginning procedure.

1.7.6.1 Frypot Baffle Inspection

1.Remove cabinet door(s) by holding door and lifting up on hinge pin. Current production model doors have spring-loaded pins that must be disengaged from the control panel and the bottom hinge. Remove marine edge (if applicable) by lifting up and off topcap and set aside.

2.The burner-tube retainer strip and burner tubes must be removed from the frypot/firebox being inspected. Remove the burner-tube shield and the burner-tube retainer from the burner-box and set aside. Lift the burner tubes up over each orifice and then pull outward to remove.

3.Disconnect the pilot gas-supply tube and remove the pilot assembly (without electronic ignition), or disconnect the

sense wire and ignition cable and remove the direct-spark ignitor assembly (with electronic ignition). Inspect frypot baffles for signs of burn-through or damage. If baffle burn-through or damage is visible, proceed to the next section. If not, and no further service to frypot/firebox is required, reverse the above steps to reassemble the fryer.

Inspect frypot baffles through burner tube opening (arrow) for signs of burn-through or damage.

1-15

Image 21
Contents 24G Series Flatbottom Gas Fryers Hour Service Hotline JunePage Computers Where Applicable FCC 24G Series Flatbottom Gas Fryers Table of Contents This page Intentionally Left Blank Functional Description NON-CE Altitudes of 2000 feet or lessCE only Altitudes of 2000 feet or less Electronic Ignition Configuration Pilot System ConfigurationControl Options No COM Relay Safety Components Accessing Fryers for ServicingAdjusting Burner Manifold Gas Pressure Cleaning the Gas Valve Vent Tube if applicableCalibrating the Thermatron Temperature Controller Adjusting the Pilot Flame where applicableLoosen two setscrews in dial arrows to recalibrate Replacing Fryer Components Remove/Replace Temperature Probe or High-Limit ThermostatTemperature probe High-limit Removing/Replacing Rocker Switches 24G Series Flatbottom GAS Fryers Service Procedures Removing/Replacing Blower Assembly or Air Prover Switch 24G Series Flatbottom GAS Fryers Service Procedures Frypot Baffle Inspection Replacing the FrypotFrypot/Firebox Removal/Replacement Procedure 24G Series Flatbottom GAS Fryers Service Procedures If the Firebox Requires Replacement Troubleshooting and Problem Isolation Ignition Failures Problems Related to the Electronic CircuitsImproper Burner Functioning 24G Series Flatbottom GAS Fryers Service Procedures Filtration Problems Improper Temperature ControlShortening to free gears Leakage Troubleshooting Guides To temperature quickly Power is present atTemperature Main Burner MalfunctionsLight Indication Probable Cause Corrective Action Indicator LightsWiring Diagrams 10.2 24G Series Single Fryers Non-CE with Boil-Out Switch 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 10.8 24G Series Single Fryers CE-Approved10.9 24GTI Oil Return/Filter System This page Intentionally Left Blank Blower Assembly, Combustion Air 24G Series Flatbottom GAS Fryers Parts ListBurner Manifold and Related Components Component Backs, Bases, Casters, Sides, Etc CabinetryNot illustrated Door Assemblies and Component Parts This page Intentionally Left Blank Flue Caps, Top Caps, and Related Components Not illustrated Control Panels, Wireways, and Related Components Component Under Fryer Filter UFF Components FiltrationComponent 24G Series Flatbottom GAS Fryers Caster, 2-inch Rigid use 810-2805 for 2-inch Swivel Caster This page Intentionally Left Blank 2 ND90 Built-In Filter System Components Line Parts Component Frypot, Drain and Oil-Return Components Component Drain Valve and Components Connectors 2-Pin Female 6-Pin Female 9-Pin Female Wiring Connectors, Pin Terminals and Power CordsService Hotline