Frymaster 2424G, 1824G manual Removing/Replacing Rocker Switches

Page 17

24G SERIES FLATBOTTOM GAS FRYERS CHAPTER 1: SERVICE PROCEDURES

IMPORTANT (High-Limit):When installing new high-limit, ensure the capillary tube and bulb are positioned properly with the mounting hardware installed prior to tightening the compression nut. Once tightened, the capillary tube cannot be repositioned.

IMPORTANT (Temperature Probe): When installing new temperature probe, ensure probe is positioned properly with the mounting hardware installed (current production systems), or 1/8" from frypot bottom (older systems), prior to tightening the compression nut. Once tightened, the

probe cannot be repositioned.

1.7.2 Removing/Replacing Rocker Switches

In older fryers, ensure probe tip is 1/8" from frypot bottom for proper temperature sensing.

Frypot Bottom

1.Disconnect the fryer from the electrical supply.

2.If switches are located on front panel or control box, remove the screws securing panel. Do not allow the panel to hang on the switch wiring harness; use some type of support.

3.Depress the retaining clips (see illustration below) and push the switch out of the slot. If there is a switch-guard present, retain it for installation of the replacement switch.

W h e n c o n n e c t i n g w i r e s t o replacement switch, pass the wires through the swi tch guard (i f applicable) before connecting to switch.

Depress clips on each end to remove switch from control panel.

4.Remove wires one at a time from the switch being removed and connect to the replacement switch until all wires are transferred.

5.Reverse the above steps for reassembly.

1-11

Image 17
Contents 24G Series Flatbottom Gas Fryers Hour Service Hotline JunePage Computers Where Applicable FCC 24G Series Flatbottom Gas Fryers Table of Contents This page Intentionally Left Blank CE only Altitudes of 2000 feet or less Functional DescriptionNON-CE Altitudes of 2000 feet or less Electronic Ignition Configuration Pilot System ConfigurationControl Options No COM Relay Safety Components Accessing Fryers for ServicingAdjusting Burner Manifold Gas Pressure Cleaning the Gas Valve Vent Tube if applicableCalibrating the Thermatron Temperature Controller Adjusting the Pilot Flame where applicableLoosen two setscrews in dial arrows to recalibrate Replacing Fryer Components Remove/Replace Temperature Probe or High-Limit ThermostatTemperature probe High-limit Removing/Replacing Rocker Switches 24G Series Flatbottom GAS Fryers Service Procedures Removing/Replacing Blower Assembly or Air Prover Switch 24G Series Flatbottom GAS Fryers Service Procedures Frypot Baffle Inspection Replacing the FrypotFrypot/Firebox Removal/Replacement Procedure 24G Series Flatbottom GAS Fryers Service Procedures If the Firebox Requires Replacement Troubleshooting and Problem Isolation Ignition Failures Problems Related to the Electronic CircuitsImproper Burner Functioning 24G Series Flatbottom GAS Fryers Service Procedures Filtration Problems Improper Temperature ControlShortening to free gears Leakage Troubleshooting Guides To temperature quickly Power is present atTemperature Main Burner MalfunctionsLight Indication Probable Cause Corrective Action Indicator LightsWiring Diagrams 10.2 24G Series Single Fryers Non-CE with Boil-Out Switch 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 10.8 24G Series Single Fryers CE-Approved10.9 24GTI Oil Return/Filter System This page Intentionally Left Blank Blower Assembly, Combustion Air 24G Series Flatbottom GAS Fryers Parts ListBurner Manifold and Related Components Component Backs, Bases, Casters, Sides, Etc CabinetryNot illustrated Door Assemblies and Component Parts This page Intentionally Left Blank Flue Caps, Top Caps, and Related Components Not illustrated Control Panels, Wireways, and Related Components Component Under Fryer Filter UFF Components FiltrationComponent 24G Series Flatbottom GAS Fryers Caster, 2-inch Rigid use 810-2805 for 2-inch Swivel Caster This page Intentionally Left Blank 2 ND90 Built-In Filter System Components Line Parts Component Frypot, Drain and Oil-Return Components Component Drain Valve and Components Connectors 2-Pin Female 6-Pin Female 9-Pin Female Wiring Connectors, Pin Terminals and Power CordsService Hotline