1.7.4.2 Replacing Direct-Spark Ignitor Assembly (Units with Electronic Ignition Only)

1.Remove the burner shield from the burner-box slots.

2.Disconnect sense wire and ignition cable from the ignitor.

3.Remove the mounting screw from the ignitor mounting-bracket and remove the ignitor.

4.Reverse the procedure to replace the ignitor assembly. Ensure the ignitor is properly positioned in relation to the center burner before tightening mounting screw.

NOTE: The above procedure is applicable to fryers equipped with electronic ignition systems only.

Ensure ignitor is properly positioned (arrow) over the center burner prior to tightening the mounting screw.

1.7.5 Removing/Replacing Blower Assembly or Air Prover Switch

1.Remove back panel. On systems with built-in filtration, use care not to damage the oil-return heat-tape wiring insulation when removing backs (multi-batteried systems after 02/03 have two-piece back panels; remove both to access blower assembly).

Multi-batteried systems after 02/03 have upper and lower back panels, which must be removed to access the blower assembly (fryer above shown with upper back panel removed).

1-13

Image 19
Contents 24G Series Flatbottom Gas Fryers Hour Service Hotline JunePage Computers Where Applicable FCC 24G Series Flatbottom Gas Fryers Table of Contents This page Intentionally Left Blank NON-CE Altitudes of 2000 feet or less Functional DescriptionCE only Altitudes of 2000 feet or less Electronic Ignition Configuration Pilot System ConfigurationControl Options No COM Relay Safety Components Accessing Fryers for ServicingAdjusting Burner Manifold Gas Pressure Cleaning the Gas Valve Vent Tube if applicableCalibrating the Thermatron Temperature Controller Adjusting the Pilot Flame where applicableLoosen two setscrews in dial arrows to recalibrate Replacing Fryer Components Remove/Replace Temperature Probe or High-Limit ThermostatTemperature probe High-limit Removing/Replacing Rocker Switches 24G Series Flatbottom GAS Fryers Service Procedures Removing/Replacing Blower Assembly or Air Prover Switch 24G Series Flatbottom GAS Fryers Service Procedures Frypot Baffle Inspection Replacing the FrypotFrypot/Firebox Removal/Replacement Procedure 24G Series Flatbottom GAS Fryers Service Procedures If the Firebox Requires Replacement Troubleshooting and Problem Isolation Ignition Failures Problems Related to the Electronic CircuitsImproper Burner Functioning 24G Series Flatbottom GAS Fryers Service Procedures Filtration Problems Improper Temperature ControlShortening to free gears Leakage Troubleshooting Guides Main Burner Malfunctions Power is present atTo temperature quickly TemperatureLight Indication Probable Cause Corrective Action Indicator LightsWiring Diagrams 10.2 24G Series Single Fryers Non-CE with Boil-Out Switch 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 10.8 24G Series Single Fryers CE-Approved10.9 24GTI Oil Return/Filter System This page Intentionally Left Blank Blower Assembly, Combustion Air 24G Series Flatbottom GAS Fryers Parts ListBurner Manifold and Related Components Component Backs, Bases, Casters, Sides, Etc CabinetryNot illustrated Door Assemblies and Component Parts This page Intentionally Left Blank Flue Caps, Top Caps, and Related Components Not illustrated Control Panels, Wireways, and Related Components Component Under Fryer Filter UFF Components FiltrationComponent 24G Series Flatbottom GAS Fryers Caster, 2-inch Rigid use 810-2805 for 2-inch Swivel Caster This page Intentionally Left Blank 2 ND90 Built-In Filter System Components Line Parts Component Frypot, Drain and Oil-Return Components Component Drain Valve and Components Connectors 2-Pin Female 6-Pin Female 9-Pin Female Wiring Connectors, Pin Terminals and Power CordsService Hotline