Frymaster 1824G, 2424G manual If the Firebox Requires Replacement

Page 24

24G SERIES FLATBOTTOM GAS FRYERS CHAPTER 1: SERVICE PROCEDURES

10.Remove firebox back, along with insulation from back of frypot. From the rear of the unit, use a prying bar to carefully pry the top assembly from the frypot and cabinet frame (single units only), and set aside. (The top assembly is secured to the frypot with high-temp silicone sealant.) On systems, remove individual pieces on the frypot being removed.

11.Pull the frypot back and up to remove. On fryers with built-in filtration systems, ensure the front oil-return inlet is clear of the firebox front before lifting frypot out of cabinet.

Use a prying bar to remove top assembly from frypot (single units only).

Remove the firebox back and insulation from back of frypot.

If the Firebox Requires Replacement:

12.Remove screws (12) securing the firebox to the cabinet braces (arrows). Lift the firebox assembly back and up to remove from cabinet.

Remove screws (arrows) securing the firebox to the cabinet.

1-18

Image 24
Contents Hour Service Hotline June 24G Series Flatbottom Gas FryersPage Computers Where Applicable FCC 24G Series Flatbottom Gas Fryers Table of Contents This page Intentionally Left Blank Functional Description NON-CE Altitudes of 2000 feet or lessCE only Altitudes of 2000 feet or less Pilot System Configuration Electronic Ignition ConfigurationControl Options No COM Relay Accessing Fryers for Servicing Safety ComponentsCleaning the Gas Valve Vent Tube if applicable Adjusting Burner Manifold Gas PressureAdjusting the Pilot Flame where applicable Calibrating the Thermatron Temperature ControllerLoosen two setscrews in dial arrows to recalibrate Remove/Replace Temperature Probe or High-Limit Thermostat Replacing Fryer ComponentsTemperature probe High-limit Removing/Replacing Rocker Switches 24G Series Flatbottom GAS Fryers Service Procedures Removing/Replacing Blower Assembly or Air Prover Switch 24G Series Flatbottom GAS Fryers Service Procedures Replacing the Frypot Frypot Baffle InspectionFrypot/Firebox Removal/Replacement Procedure 24G Series Flatbottom GAS Fryers Service Procedures If the Firebox Requires Replacement Troubleshooting and Problem Isolation Problems Related to the Electronic Circuits Ignition FailuresImproper Burner Functioning 24G Series Flatbottom GAS Fryers Service Procedures Improper Temperature Control Filtration ProblemsShortening to free gears Leakage Troubleshooting Guides Power is present at To temperature quicklyTemperature Main Burner MalfunctionsIndicator Lights Light Indication Probable Cause Corrective ActionWiring Diagrams 10.2 24G Series Single Fryers Non-CE with Boil-Out Switch 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures Single Fryers CE-Approved 10.8 24G Series10.9 24GTI Oil Return/Filter System This page Intentionally Left Blank 24G Series Flatbottom GAS Fryers Parts List Blower Assembly, Combustion AirBurner Manifold and Related Components Component Cabinetry Backs, Bases, Casters, Sides, EtcNot illustrated Door Assemblies and Component Parts This page Intentionally Left Blank Flue Caps, Top Caps, and Related Components Not illustrated Control Panels, Wireways, and Related Components Component Filtration Under Fryer Filter UFF ComponentsComponent 24G Series Flatbottom GAS Fryers Caster, 2-inch Rigid use 810-2805 for 2-inch Swivel Caster This page Intentionally Left Blank 2 ND90 Built-In Filter System Components Line Parts Component Frypot, Drain and Oil-Return Components Component Drain Valve and Components Wiring Connectors, Pin Terminals and Power Cords Connectors 2-Pin Female 6-Pin Female 9-Pin FemaleService Hotline