Frymaster 1824G, 2424G manual Pilot System Configuration, Electronic Ignition Configuration

Page 8

24G SERIES FLATBOTTOM GAS FRYERS CHAPTER 1: SERVICE PROCEDURES

An electromechanical gas valve regulates gas flow to the manifold. 24G Series Flatbottom gas fryers are equipped with either a 120-volt valve system (standing pilot) or a 24-volt valve system (electronic ignition or CE standing pilot). Units may be configured with either a pilot ignition system (standing pilot) or an electronic ignition system (direct spark ignition).

Pilot System Configuration

The pilot system is comprised of the pilot orifice, pilot hood, and a thermocouple. The pilot serves two purposes. The first is to light the burner, the second is to heat the thermocouple. In operation, the thermocouple is in contact with the pilot flame and generates millivolts. The millivolt output energizes the gas valve pilot coil, which in turn opens the pilot valve. If the pilot flame is extinguished, voltage is lost to the gas valve pilot coil and the pilot valve closes. The gas valve is constructed so that the main valve will not open if the pilot valve is not open. The pilot flame must be manually lit when the fryer is first placed into operation. A separate circuit, activated by the fryer ON/OFF switch, provides voltage through the Thermatron temperature controller to the gas valve main coil, which opens the main valve.

 

 

 

 

 

Main Coil

 

 

 

 

 

Gas

 

 

 

 

 

Valve

 

 

 

 

 

Pilot Coil

 

 

 

 

Thermocouple

 

 

 

 

 

High-Limit

 

 

14

NC

RELAY

Thermostat

 

 

12 13

COM

Pilot

 

 

NO

 

 

10 11

PROBE

 

 

 

 

9

1A

EXT POT

 

 

 

7 8

3A 2A

 

Line Voltage

 

3

AC2

 

 

 

 

2

AC1

 

 

 

 

1

 

 

 

 

6

5

 

 

ON/

Line Voltage

MELT CYCLE DISABLE

 

 

Thermatron Temperature

 

OFF

 

 

Switch

The Pilot System

Controller

 

 

 

 

 

 

 

 

120V

Electronic Ignition Configuration

In units configured for electronic ignition, an ignition module connected to an ignitor assembly replaces the pilot system. The ignition module performs three important functions: it provides an ignition spark, supplies voltage to the gas valve, and proofs the burner flame.

The module contains a time delay circuit and a coil that activates the gas valve. The ignitor assembly consists of a spark plug and a flame sensor element.

At start-up the ON/OFF switch is placed in the "ON" position, supplying 115 VAC or 230 VAC, according to system configuration, to the Thermatron interface board. The voltage is stepped down

1-2

Image 8
Contents Hour Service Hotline June 24G Series Flatbottom Gas FryersPage Computers Where Applicable FCC 24G Series Flatbottom Gas Fryers Table of Contents This page Intentionally Left Blank CE only Altitudes of 2000 feet or less Functional DescriptionNON-CE Altitudes of 2000 feet or less Pilot System Configuration Electronic Ignition ConfigurationControl Options No COM Relay Accessing Fryers for Servicing Safety ComponentsCleaning the Gas Valve Vent Tube if applicable Adjusting Burner Manifold Gas PressureAdjusting the Pilot Flame where applicable Calibrating the Thermatron Temperature ControllerLoosen two setscrews in dial arrows to recalibrate Remove/Replace Temperature Probe or High-Limit Thermostat Replacing Fryer ComponentsTemperature probe High-limit Removing/Replacing Rocker Switches 24G Series Flatbottom GAS Fryers Service Procedures Removing/Replacing Blower Assembly or Air Prover Switch 24G Series Flatbottom GAS Fryers Service Procedures Replacing the Frypot Frypot Baffle InspectionFrypot/Firebox Removal/Replacement Procedure 24G Series Flatbottom GAS Fryers Service Procedures If the Firebox Requires Replacement Troubleshooting and Problem Isolation Problems Related to the Electronic Circuits Ignition FailuresImproper Burner Functioning 24G Series Flatbottom GAS Fryers Service Procedures Improper Temperature Control Filtration ProblemsShortening to free gears Leakage Troubleshooting Guides Power is present at To temperature quicklyTemperature Main Burner MalfunctionsIndicator Lights Light Indication Probable Cause Corrective ActionWiring Diagrams 10.2 24G Series Single Fryers Non-CE with Boil-Out Switch 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures 24G Series Flatbottom GAS Fryers Service Procedures Single Fryers CE-Approved 10.8 24G Series10.9 24GTI Oil Return/Filter System This page Intentionally Left Blank 24G Series Flatbottom GAS Fryers Parts List Blower Assembly, Combustion AirBurner Manifold and Related Components Component Cabinetry Backs, Bases, Casters, Sides, EtcNot illustrated Door Assemblies and Component Parts This page Intentionally Left Blank Flue Caps, Top Caps, and Related Components Not illustrated Control Panels, Wireways, and Related Components Component Filtration Under Fryer Filter UFF ComponentsComponent 24G Series Flatbottom GAS Fryers Caster, 2-inch Rigid use 810-2805 for 2-inch Swivel Caster This page Intentionally Left Blank 2 ND90 Built-In Filter System Components Line Parts Component Frypot, Drain and Oil-Return Components Component Drain Valve and Components Wiring Connectors, Pin Terminals and Power Cords Connectors 2-Pin Female 6-Pin Female 9-Pin FemaleService Hotline