Frymaster 1814E operation manual Power Requirements, Three 3 Phase Requirements

Page 11

2.2Power Requirements

Three (3) Phase Requirements

 

MODEL

VOLTAGE

WIRE

 

SERVICE

 

 

 

 

 

 

 

 

1814E 14kW

208

3

 

1814E 14kW

240

3

 

1814E 14kW

480

3

 

1814E 14kW

220/380

4

 

1814E 14kW

240/415

4

 

1814E 14kW

230/400

4

 

1814E 17kW

208

3

 

1814E 17kW

240

3

 

1814E 17kW

480

3

 

1814E 17kW

220/380

4

 

1814E 17kW

240/415

4

 

1814E 17kW

230/400

4

 

1814E 22kW

208

3

 

1814E 22kW

240

3

 

1814E 22kW

480

3

 

1814E 22kW

220/380

4

 

1814E 22kW

240/415

4

 

1814E 22kW

230/400

4

MINIMUM WIRE

AMPS

 

SIZE

 

(per leg)

AWG

 

(mm)

 

 

6

 

(4.11)

39

6

 

(4.11)

34

8

 

(2.59)

17

6

 

(4.11)

21

6

 

(4.11)

20

6

 

(4.11)

21

6

 

(4.11)

48

6

 

(4.11)

41

6

 

(4.11)

21

6

 

(4.11)

26

6

 

(4.11)

24

6

 

(4.11)

25

4

 

(5.19)

61

4

 

(5.19)

53

6

 

(4.11)

27

6

 

(4.11)

34

6

 

(4.11)

31

6

 

(4.11)

32

Single Phase Requirements

MODEL

VOLTAGE

WIRE

SERVICE

 

 

 

 

 

1814E 14kW

208

2

1814E 14kW

240

2

1814E 14kW

480

2

MINIMUM WIRE

AMPS

 

SIZE

 

(per leg)

AWG

 

 

(mm)

 

 

 

3

 

 

(5.83)

68

4

 

 

(5.19)

59

8

 

 

(3.26)

30

NOTICE

If this appliance is permanently connected to fixed wiring, it must be connected by means of copper wires having a temperature rating of not less than 167°F (75°C).

DANGER

This appliance must be connected to a power supply having the same voltage and phase as specified on the rating plate located on the inside of the appliance door.

DANGER

All wiring connections for this appliance must be made in accordance with the wiring diagram(s) furnished with the appliance. Refer to the wiring diagram(s) affixed to the inside of the appliance door when installing or servicing this equipment.

2.3Positioning the Fryer

DANGER

No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster Service Hotline at 1-800-551-8633.

2-3

Image 11
Contents Frymaster 1814E Series Electric Fryer Hour Service HotlineCanada Page Typical Configuration 31814E Shown Table of Contents Controller Information Safety InformationGeneral Definitions European Community CE Specific InformationService Information Shipping Damage Claim ProcedureGeneral Australian Requirements Clearance and VentilationThree 3 Phase Requirements Power RequirementsFrypot Boil Out Page Equipment Setup and Shutdown Procedures Controllers ShutdownPage Filter Preparation Filter Components Assembling the Filter Return filter pan to cabinet Installing the Filter Filtering Tools Operating the Filter 4.5.1 Filter Operation Overfill the Frypot Filter OperationFilter Pump Reset Switch Draining and Disposing of Waste Oil Clean the Frypot and Heating Elements- Weekly Fryer Annual/Periodic System InspectionBuilt-In Filtration System Page Introduction Before calling a service agent or the Frymaster HotlineTroubleshooting Controller and Heating Problems Problem Probable Causes Corrective ActionError Messages Filtration ProblemsFilter Pan Components User Replaceable PartsPart Number Description This page Intentionally Left Blank Service Hotline