Frymaster 1814E operation manual Assembling the Filter

Page 19

4.3.2Assembling the Filter

1.Place the support grid in the bottom of filter pan.

Support grid properly placed in filter pan.

2.Put one filter paper sheet on top of the support grid. Be sure the paper covers the filter pan bottom and laps two inches onto the pan wall.

3.Position the hold-down ring on top of the filter paper. Ensure the hold-down ring seals around the support grid. This prevents sediment from getting into the system.

Ensure filter paper overlaps two inches on all sides and is evenly distributed under the hold- down ring.

Hold-down ring positioned correctly over filter paper in filter pan.

4-4

Image 19
Contents Frymaster 1814E Series Electric Fryer Hour Service HotlineCanada Page Typical Configuration 31814E Shown Table of Contents General Safety InformationController Information Definitions European Community CE Specific InformationService Information Shipping Damage Claim ProcedureGeneral Australian Requirements Clearance and VentilationThree 3 Phase Requirements Power RequirementsFrypot Boil Out Page Equipment Setup and Shutdown Procedures Controllers ShutdownPage Filter Preparation Filter Components Assembling the Filter Return filter pan to cabinet Installing the Filter Filtering Tools Operating the Filter 4.5.1 Filter Operation Overfill the Frypot Filter OperationFilter Pump Reset Switch Draining and Disposing of Waste Oil Clean the Frypot and Heating Elements- Weekly Fryer Annual/Periodic System InspectionBuilt-In Filtration System Page Introduction Before calling a service agent or the Frymaster HotlineTroubleshooting Controller and Heating Problems Problem Probable Causes Corrective ActionError Messages Filtration ProblemsPart Number Description User Replaceable PartsFilter Pan Components This page Intentionally Left Blank Service Hotline