Frymaster 1814E operation manual Problem Probable Causes Corrective Action

Page 32

6.2Troubleshooting

6.2.1 Controller and Heating Problems

Problem

Probable Causes

Corrective Action

 

A. Power cord is not plugged in or

A. Plug power cord in and verify

 

that circuit breaker is not

 

circuit breaker is tripped.

Controller won't

tripped.

 

activate.

B. Controller or power supply

B. Call a FAS.

 

component or interface board has

 

 

failed.

 

 

 

A. A drain safety switch prevents

 

 

the heating element from being

 

A. Drain valve is open.

energized if the drain valve is

Fryer does not heat.

 

not fully closed. Verify that the

 

 

drain valve is fully closed.

 

B. One or more other components

B. Call a FAS.

 

have failed.

 

 

 

This is normal. The default

 

 

operational mode is for the

 

 

elements to cycle on and off until

 

 

the temperature in the frypot

 

 

reaches 180ºF (82ºC). MLT-

Fryer repeatedly

 

CYCL will appear in the display

 

when in the melt-cycle mode. The

cycles on and off

Fryer is in melt-cycle mode.

purpose of the melt-cycle is to

when first started.

 

 

allow controlled melting of solid

 

 

 

 

shortening to prevent scorching

 

 

and flash fires or damage to the

 

 

element. To bypass melt cycle

 

 

press and hold the exit cool button.

 

 

When prompted, press yes.

 

 

This fryer is equipped with a drain

Fryer does not heat

 

safety switch that prevents the

Drain valve is open.

heating element from being

after filtering.

energized if the drain valve is not

 

 

 

fully closed. Verify that the drain

 

 

valve is fully closed.

Fryer heats until

Temperature probe or controller has

Turn fryer off and call a FAS.

high limit trips with

failed.

 

heat indicator ON.

 

 

 

Fryer heats until

 

 

high limit trips

Contactor or controller has failed.

Call a FAS.

without heat

 

 

indicator ON.

 

 

Fryer stops heating

The high limit thermostat or

Call a FAS.

with heat indicator

 

contactor has failed.

 

ON.

 

 

 

6-2

Image 32
Contents Hour Service Hotline Frymaster 1814E Series Electric FryerCanada Page Typical Configuration 31814E Shown Table of Contents Controller Information Safety InformationGeneral European Community CE Specific Information DefinitionsShipping Damage Claim Procedure Service InformationGeneral Clearance and Ventilation Australian RequirementsPower Requirements Three 3 Phase RequirementsFrypot Boil Out Page Equipment Setup and Shutdown Procedures Shutdown ControllersPage Filter Preparation Filter Components Assembling the Filter Return filter pan to cabinet Installing the Filter Filtering Tools Operating the Filter 4.5.1 Filter Operation Filter Operation Overfill the FrypotFilter Pump Reset Switch Draining and Disposing of Waste Oil Clean the Frypot and Heating Elements- Weekly Annual/Periodic System Inspection FryerBuilt-In Filtration System Page Before calling a service agent or the Frymaster Hotline IntroductionProblem Probable Causes Corrective Action Troubleshooting Controller and Heating ProblemsFiltration Problems Error MessagesFilter Pan Components User Replaceable PartsPart Number Description This page Intentionally Left Blank Service Hotline