Frymaster 1814E operation manual Equipment Setup and Shutdown Procedures

Page 14

FRYMASTER 1814E SERIES ELECTRIC FRYER

CHAPTER 3: OPERATING INSTRUCTIONS

3.1Equipment Setup and Shutdown Procedures

Setup

DANGER

Never operate the appliance with an empty frypot. The frypot must be filled to the bottom fill line with water, oil or shortening before energizing the elements. Failure to do so will result in irreparable damage to the elements and may cause a fire.

DANGER

Remove all drops of water from the frypot before filling with oil. Failure to do so will cause spattering of hot liquid when the oil is heated to cooking temperature.

1.Fill the frypot with oil to the bottom OIL LEVEL line located on the rear of the frypot. This will allow for oil expansion as heat is applied. Do not fill cold oil any higher than the bottom line; overflow may occur as heat expands the oil.

2.NOTE: If solid shortening is used, first raise the elements, then pack the shortening into the bottom of the frypot. Lower the elements, and then pack the shortening around and over the elements. It may be necessary to add shortening to bring the level up to the proper mark after the packed shortening has melted. Never insert a solid block of shortening into frypot on top of the elements. Hot spots and element damage will occur, and the potential for flash-fire increases.

DANGER

Never set a complete block of solid shortening on top of the heating elements.

When using solid shortening, always pre-melt the shortening before adding it to the frypot. If the shortening is not pre-melted, it must be packed down into the bottom of the frypot and between the elements, and the fryer must be started in the melt-cycle mode.

Never cancel the melt-cycle mode when using solid shortening. Doing so will result in damage to the elements and increase the potential for a flash fire.

3.Ensure that the power cord(s) is/are plugged into the appropriate receptacle(s). Verify that the face of the plug is flush with the outlet plate, with no portion of the prongs visible.

4.Ensure that the power is switched on. Some models are equipped with a master switch located behind the fryer door cabinet on the front panel of the component box, next to the fuse. off is displayed on the controller.

5.Ensure that the controller is switched ON by pressing the ON/OFF switch to the ON position.

6.Ensure that the oil level is at the top OIL LEVEL line when the oil is at its cooking temperature. It may be necessary to add oil or shortening to bring the level up to the proper mark, after it has reached cooking temperature. If solid shortening is used, the MELT cycle MUST be used to

3–1

Image 14
Contents Hour Service Hotline Frymaster 1814E Series Electric FryerCanada Page Typical Configuration 31814E Shown Table of Contents Controller Information Safety InformationGeneral European Community CE Specific Information DefinitionsShipping Damage Claim Procedure Service InformationGeneral Clearance and Ventilation Australian RequirementsPower Requirements Three 3 Phase RequirementsFrypot Boil Out Page Equipment Setup and Shutdown Procedures Shutdown ControllersPage Filter Preparation Filter Components Assembling the Filter Return filter pan to cabinet Installing the Filter Filtering Tools Operating the Filter 4.5.1 Filter Operation Filter Operation Overfill the FrypotFilter Pump Reset Switch Draining and Disposing of Waste Oil Clean the Frypot and Heating Elements- Weekly Annual/Periodic System Inspection FryerBuilt-In Filtration System Page Before calling a service agent or the Frymaster Hotline IntroductionProblem Probable Causes Corrective Action Troubleshooting Controller and Heating ProblemsFiltration Problems Error MessagesFilter Pan Components User Replaceable PartsPart Number Description This page Intentionally Left Blank Service Hotline