Frymaster 1814E operation manual Filter Preparation

Page 17

the oil or shortening, Frymaster recommends that a Frymaster filter cone holder and filter cone be used when a filter machine is not available. If you are using a Frymaster filter cone holder, be sure that the cone holder rests securely on the metal container.

3.Open the drain valve slowly to avoid splattering. If the drain valve becomes clogged with food particles, use the Fryer’s Friend (poker-like tool) to clear the blockage.

DANGER

NEVER attempt to clear a clogged drain valve from the front of the valve! Hot oil will rush out creating the potential for severe burns.

DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage to the ball inside will result in leaks and will void the Frymaster warranty.

4.After draining the oil, clean all food particles and residual oil from the frypot. BE CAREFUL, this material may still cause severe burns if it comes in contact with bare skin.

5.Close the drain valve securely and fill the frypot with clean, filtered or fresh oil or solid shortening to the bottom OIL-LEVELline.

DANGER

When using solid shortening, pack the shortening down into the bottom of the frypot. DO NOT operate the fryer with a solid block of shortening sitting in the upper portion of the frypot. This will cause damage to the frypot and may cause a flash fire.

4.2 General Filtration Information

Most filter systems use filter paper as the filter medium. Filter powder is required to enhance the filtration process. Photos used in the procedural illustrations may differ from the filter unit that came with the frying system. The following procedures apply to all fryers equipped with filter systems. Filter system design depends on the frying system configuration.

4.3Filter Preparation

On initial installation and before each use, clean the filter:

a.Remove all loose parts from the filter,

b.Wash the filter pan and all accessories in hot, soapy water,

c.Dry thoroughly.

4-2

Image 17
Contents Frymaster 1814E Series Electric Fryer Hour Service HotlineCanada Page Typical Configuration 31814E Shown Table of Contents Controller Information Safety InformationGeneral Definitions European Community CE Specific InformationService Information Shipping Damage Claim ProcedureGeneral Australian Requirements Clearance and VentilationThree 3 Phase Requirements Power RequirementsFrypot Boil Out Page Equipment Setup and Shutdown Procedures Controllers ShutdownPage Filter Preparation Filter Components Assembling the Filter Return filter pan to cabinet Installing the Filter Filtering Tools Operating the Filter 4.5.1 Filter Operation Overfill the Frypot Filter OperationFilter Pump Reset Switch Draining and Disposing of Waste Oil Clean the Frypot and Heating Elements- Weekly Fryer Annual/Periodic System InspectionBuilt-In Filtration System Page Introduction Before calling a service agent or the Frymaster HotlineTroubleshooting Controller and Heating Problems Problem Probable Causes Corrective ActionError Messages Filtration ProblemsFilter Pan Components User Replaceable PartsPart Number Description This page Intentionally Left Blank Service Hotline