K-Tec MT2000 manual List of Figures, Appendices

Page 3

TABLE OF CONTENTS (CONTINUED)

9. APPENDICES

23

9.1

APPENDIX A: Sensor Trim

23

9.2

APPENDIX B: Additional Special Functions in the CFG2 (Hidden) Menu

24

9.3

APPENDIX C: Linearization

26

9.4

APPENDIX D: Interface Applications

27

9. 5

APPENDIX E: Oscilloscope Use & Setup for Troubleshooting

28

 

9.5.1

General Setup

28

 

9.5.2

Use and Setup of the Oscilloscope for the MT2000

28

9. 6

APPENDIX F: CE Certification of Conformity

29

9. 7

APPENDIX G: Exida Certificate

30

9.8

APPENDIX H: Installation Drawings for Intrinsic Safety & Standard Wiring

31

9.9

APPENDIX I: Mounting Configurations

34

9.10 APPENDIX J: Warranty Statement

35

Figure 2.1

Direct Reflect Mode

6

LIST OF FIGURES

Figure 3.1

Mounting Requirements

7

Figure 3.2

Factory Default Configuration

8

Figure 4.1

Quikstart Procedure

10

Figure 4.2

Electronics LCD Display

10

Figure 4.3

Transmitter Configuration from Model Number

12

Figure 4.4

L10 Advanced Parameter Settings

13

Figure 4.5

Ultra Low Dielectric (ULD) Mode Configuration

16

Figure 4.6

Example of Display in Calibration Mode

18

Figure 4.7

Write Project (right jumper)

18

Figure 9.1

Sensor Trim (Factory Defaults)

23

Figure 9.2

Configuration 2 (hidden) Menu

24

Figure 9.3

MT2000 Interface

27

Figure 9.4

Oscilloscope Use & Setup for Troubleshooting

28

Figure 9.5

Mounting Configurations

31

MT2000-0200-1 Rev f (10-2007) DCN0160

3

Image 3
Contents Guided Wave Radar Level Transmitter Table of Contents Appendices List of FiguresIntroduction Measurement cycle consists of the following Ambient TemperatureOverview Storage InformationUltra Low Dielectric ULD Measure Method Direct Reflect Mode standard cont’dMounting Requirements InstallationURV = Probe Length LRV = 0 in. / 0 mm Factory Default ConfigurationShortening of Probe MT2000 Guided Wave Radar GuidelinesMT2000 Guided Wave Radar Guidelines cont’d WiringQuickstart Procedure CommissioningQuickstart Procedure cont’d Verify Proper Power-UpSetting the 4mA and 20 mA Points Using the Pushbutton Menu Calibration Menu LCD Menu OperationThreshold Level Parameter THV and Gain Setting GS Detailed Configuration Parameters Direct Mode Blanking MenuThreshold Level Parameter THV and Gain Setting GS cont’d Advanced Parameter SettingsL1O KO & KG Advanced Parameter Settings cont’dUltra Low Dielectric ULD Mode Configuration = H * Sqrt DC H + LDC = I + H L / H2 DAC TrimFigure Ultra Low Dielectric ULD Mode Configuration cont’dAdvanced Output Configuration Setting the DAC trimBench Calibration of the 4mA & 20mA Points 6 4mA & 20mA Calibration Using Actual Level InputJumper Switch Settings Reversing The Output Action Using Actual Level InputTroubleshooting Information Possible SymptomsValid Current Loop Outputs Interoperability and Conformance Class Possible Symptoms cont’dElectronics Module Replacement Honeywell DE Output OptionCompatibility Hart Protocol Interface OptionOperating Modes Hart CommunicatorLRV Glossary of TermsAppendix a Sensor Trim AppendicesEND CFG Menu Configuration 2 Hidden MenuTMP To clear the linearization table To access the linearization tableSetting up Linearization Table Points Appendix C LinearizationMT2000 Interface Appendix D Interface ApplicationsChannel B Use and setup of the oscilloscope for the MT2000Scope Settings Channel a PrerequisitesAppendix F CE Certificate of Conformity Appendix G Exida Certificate MT2000-0200-1 Rev f 10-2007 DCN0160 MT2000-0200-01 Rev f 10-2007 DCN0160 MT2000-0200-1 Rev f 10-2007 DCN0160 10b Appendix I Mounting Configurations3a, 3b 10aYear Warranty for Appendix J Warranty Statement