34-ST-03-64 Page 20

Model Selection Guide (34-ST-16-32)

Model Selection Guide

34-ST-16-32 Issue 39

Instructions

Select the desired Key Number. The arrow to the right marks the selection available.

Make one selection from each Table I and II using the column below the proper arrow.

Select as many Table III options as desired (if no options or approvals are desired, specify 9X).

A () denotes unrestricted availability. A letter denotes restricted availability.

Restrictions follow Table IV.

Key Number

_ _ _ _ _ _

I

- _ _ _

-

II

_ _ _ _ _ _ _ _ _ _ _ _

-

III (Optional)

 

IV

_ _ , _ _

+

XXXX

KEY NUMBER

 

 

 

 

 

 

 

 

 

Description

Selection

Availability

0-10" to 0-400" H2O/0-25 to 0-1,000 mbar

STR12D

 

 

 

Body Rating*: 2,500 psi (172 bar) Compound Characterized

 

 

 

 

 

 

 

0-5 to 0-100 psi/0-0.34 to 0-7 bar

STR13D

 

 

 

Body Rating*: 2,500 psi (172 bar)

 

 

 

 

 

 

 

0-5 to 0-500 psia/0-0.34 to 0-35 bar

STR14A

 

 

 

Body Rating*: 500 psi (35 bar)

 

 

 

 

 

 

 

0-5 to 0-500 psi/0-0.34 bar to 0-35 bar

STR14G

 

 

 

Body Rating*: 500 psi (35 bar)

 

 

 

 

 

 

 

0-100 to 0-3,000 psi/0-7 bar to 210 bar

STR17G

 

 

 

Body Rating*: 3,000 psi (210 bar)

 

 

 

 

 

 

 

* Remote seal system pressure rating is body rating or seal rating, whichever is less.

Important Note:

Base STR models no longer include a default communications option. All units now require the

selection of a communication option from Table III (AN, DE, HC, H6 or FF).

 

 

 

 

 

 

 

 

TABLE I - METER BODY

Selection

 

 

 

 

 

 

 

 

 

 

1 Remote Seal (High Side)

1 _ _

 

Number of Seals

 

 

2 Remote Seals

2 _ _

 

 

 

 

 

1 Remote Seal (Low Side)

3 _ _

 

 

 

 

 

 

 

 

 

 

 

 

Value Added Model (VAM unit)

5 _ _

8

8

8

 

Fill Fluid

 

 

Silicone (DC 200)

_ 1 _

 

(Meter body)

 

 

 

CTFE

_ 2 _

q

q

q

 

Construction

 

 

Non-Wetted Adapter Head Material

 

 

 

 

 

In-Line Gauge

 

 

316 SS Bonnet

_ _ A

 

 

 

 

 

316 SS Bonnet for Close-Couple

_ _ D

 

 

y

 

 

 

 

 

 

 

 

 

 

316 SS (bolt-on heads)

_ _ A

 

 

 

Dual Head DP

 

 

316 SS for Close-Couple

_ _ D

y

 

 

 

 

 

 

316 SS with all-welded meter body

_ _ C

7

 

 

 

Single Head

 

 

316 SS Adapter Head

_ _ A

 

 

 

Absolute

 

 

316 SS Head for Close-Couple

_ _ D

 

y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In-Line Gauge

Dual Head DP

All welded

Image 20
Contents Guide IntroductionDescription of Diaphragm Seals 34-ST-03-64Stainless Steel Nipples are available Features DescriptionSpecifications Operating Conditions All Models Parameter Description Parameter Upper Range Limit Psig Bar Minimum Span Psig Turndown Ratio±0.10 + Or ±0.10 + Performance Under Rated Conditions General for all Models Physical and Approval Bodies 34-ST-03-64 Parameter Description 34-ST-03-64 Supply voltage/loop resistance chart Transmitter below datum Transmitter above datumTransmitter at datum Density, direct acting instrument configuration With Horizontal Pipe MountLGP/I Remote Seal DP/I Remote SealWith Vertical Pipe Mount AP/I Remote Seal with Vertical Pipe MountLGP/I Remote Seal With Vertical PipeOptions Instructions Table II Seals Table II Seals Two 1/2 with plastic plugs Ansi Class 150/300/600 GFA Two 1/4 with plastic plugs Table II Seals MD0NE0 PF0 QG0 Wetted MaterialTransmitter Mounting Brackets Options Warranty Options Table III OptionsCont’d See in Specification Dimensions and Drawings 21a Flush Flanged SealDimensions and Drawings, Dimensions and Drawings, Dimensions and Drawings, Dimensions and Drawings, This page Intentionally Blank