Honeywell STR12D warranty Transmitter Mounting Brackets Options

Page 27

 

 

 

 

 

34-ST-03-64

 

 

 

 

 

 

Page 27

 

 

 

 

STR14A

 

 

TABLE III - OPTIONS

STR12D & 13D

 

 

 

14G & 17G

 

 

 

 

 

 

 

 

 

 

Communication Options (Must choose a communications option)

 

 

 

 

 

 

 

Analog only (can be configured using appropriate Honeywell DE tool)

AN

 

 

DE Protocol communications

DE

 

 

HART 5.x Protocol compatible electronics

HC

e

e

e

 

b

HART 6.x Protocol compatible electronics

H6

e

e

e

 

 

FOUNDATION Fieldbus Communications

FF

r

r

r

 

 

Indicating Meter Options

 

 

 

 

 

 

 

Analog Meter (0-100 Even 0-10 Square Root)

ME

 

 

b

Smart Meter

SM

 

 

Custom Configuration of Smart Meter

CI

f

f

f

 

 

Local Zero & Span

ZS

m

 

m

 

b

 

 

Local Zero

LZ

x

 

x

 

 

 

 

 

 

Transmitter Housing & Electronics Options

 

 

 

 

 

 

 

NAMUR Failsafe Software

NE

15

15

15

 

 

SIL 2 - TÜV Certified transmitter (requires HC or H6 and WP options)

SL

14

14

14

 

 

Lightning Protection

LP

 

 

Custom Calibration and I.D. in Memory

CC

 

 

Transmitter Configuration - (non-Fieldbus)

TC

15

15

15

 

 

Transmitter Configuration - (Fieldbus)

FC

21

21

21

 

 

Write Protection (Delivered in the "enabled" position)

WP

 

 

 

b

Write Protection (Delivered in the "disabled" position)

WX

 

 

 

316 SS Electronics Housing - with M20 Conduit Connections

SH

n

n

n

 

 

1/2" NPT to M20 316 SS Conduit Adapter (BASEEFA EEx d IIC)

A1

n

n

n

 

b

1/2" NPT to 3/4" NPT 316 SS Conduit Adapter

A2

u

u

u

 

Stainless Steel Housing with M20 to 1/2" NPT 316 SS Conduit

A3

i

i

i

 

 

Adapter (use for FM and CSA Approvals)

 

 

 

 

 

 

 

 

 

Stainless Steel Customer Wired-On Tag

TG

 

 

b

(4 lines, 28 characters per line, customer supplied information)

 

 

 

 

 

 

 

Stainless Steel Customer Wired-On Tag (blank)

TB

 

 

End Cap Live Circuit Warning Label in Spanish (only with ATEX 3D)

SP

a

a

a

 

b

End Cap Live Circuit Warning Label in Portuguese (only with ATEX 3D)

PG

a

a

a

 

End Cap Live Circuit Warning Label in Italian (only with ATEX 3D)

TL

a

a

a

 

 

End Cap Live Circuit Warning Label in German (only with ATEX 3D)

GE

a

a

a

 

 

Meter Body Options (Seal bolt material depends on Transmitter bolt material)

 

 

 

 

 

 

 

A286 SS (NACE) Bolts and 304 SS (NACE) Nuts for Heads

CR

 

 

b

316 SS Bolts and 316 SS Nuts for Process Heads

SS

 

 

 

B7M Bolts and Nuts for Process Heads

B7

 

 

 

 

Remote Seal Options

 

 

 

 

 

 

 

Gold Plated Seal Diaphragm (1 Seal)

G1

j

j

j

 

 

Gold Plated Seal Diaphragm (2 Seals)

G2

j

 

 

 

b

Teflon Coated Seal Diaphragm (1 Seal) - only for anti-sticking

N1

j

j

j

 

Teflon Coated Seal Diaphragms(2 Seals) - only for anti-sticking

N2

j

 

 

 

 

Transmitter Mounting Brackets Options

 

 

 

 

 

 

 

Mounting Bracket - Carbon Steel

MB

 

b

Mounting Bracket - 304 SS

SB

 

Flat Mounting Bracket

FB

 

 

Services/Certificates Options

 

 

 

 

 

 

 

Users Manual Paper Copy (Standard, HC/H6 or FF ships accordingly)

UM

 

 

Clean Transmitter for Oxygen or Chlorine Service with Certificate

0X

h

h

h

 

 

Over-Pressure Leak Test with F3392 Certificate

TP

 

 

Calibration Test Report and Certificate of Conformance (F3399)

F1

 

b

 

Certificate of Conformance (F3391)

F3

 

 

 

Certificate of Origin (F0195)

F5

 

 

FMEDA Certificate (SIL 1) (FC33321)

F6

 

b

 

SIL Certificate (SIL 2/3) (FC33337)

FE

22

22

22

 

 

 

NACE Certificate (Process-Wetted & Non-Process Wetted) (FC33339)

F7

 

b

NACE Certificate (Process-Wetted only) (FC33338)

FG

o

o

 

NACE Certificate (F0198) for all welded meter bodies only

F8

16

 

 

 

 

Marine Type Approvals (DNV, ABS, BV, KR & LR)

MT

2

2

2

 

 

Image 27
Contents Introduction Guide34-ST-03-64 Description of Diaphragm SealsStainless Steel Nipples are available Description FeaturesSpecifications Operating Conditions All Models Parameter Description Parameter Bar Minimum Span Psig Turndown Ratio Upper Range Limit Psig±0.10 + Or ±0.10 + Performance Under Rated Conditions General for all Models Physical and Approval Bodies 34-ST-03-64 Parameter Description 34-ST-03-64 Supply voltage/loop resistance chart Transmitter above datum Transmitter at datumTransmitter below datum Density, direct acting instrument configuration DP/I Remote Seal With HorizontalPipe Mount LGP/I Remote SealWith Vertical Pipe With Vertical Pipe MountAP/I Remote Seal with Vertical Pipe Mount LGP/I Remote SealOptions Instructions Table II Seals Table II Seals Two 1/2 with plastic plugs Ansi Class 150/300/600 GFA Two 1/4 with plastic plugs PF0 QG0 Wetted Material Table II SealsMD0 NE0Transmitter Mounting Brackets Options Table III Options Warranty OptionsCont’d See in Specification 21a Flush Flanged Seal Dimensions and DrawingsDimensions and Drawings, Dimensions and Drawings, Dimensions and Drawings, Dimensions and Drawings, This page Intentionally Blank