Honeywell STR12D warranty Parameter

Page 7

34-ST-03-64 Page 7

Performance Under Rated Conditions * - Model STR13D (0-5 to 0-100 psid)

Parameter

Upper Range Limit **

psid

 

bar

 

 

Minimum Span

psid

 

bar

 

 

Turndown Ratio

 

Zero Elevation and Suppression

Accuracy (Reference – Includes combined effects of linearity, hysteresis, and repeatability)

Stated accuracy does not apply for models with 2.9 inch diameter remote seal diaphragms.

Accuracy includes residual error after averaging successive readings.

For FOUNDATION Fieldbus use Digital Mode specifications. For HART use Analog Mode specifications.

Combined Zero and Span Temperature Effect per 28°C (50°F) ***

Description

100

7

5

0.35

20 to 1

No limit except minimum span within –18% and +100% of URL. Specifications valid from –5% to 100% of URL.

In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is greater, terminal based.

For URV below reference point (30 psi), accuracy equals:

 

30 psi

 

2 bar

±0.05 + 0.05 (

 

) or

±0.05 + 0.05 (

 

) in % of span

span psi

span bar

In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is greater, terminal based.

For URV below reference point (30 psi), accuracy equals:

 

30 psi

 

2 bar

±0.025 + 0.05 (

 

) or ±0.025 + 0.05

(

 

) in % of span

span psi

span bar

In Analog Mode: ±0.33% of span.

For URV below reference point (60 psi), effect equals:

±0.05 + 0.2

60 psi

4 bar

In % span

span psi

or ±0.05 + 0.28

span bar

 

 

 

 

 

 

In Digital Mode: ±0.305% of span.

For URV below reference point (60 psi), effect equals:

 

60 psi

4 bar

 

±0.025 + 0.25

span psi

or ±0.025 + 0.28

span bar

In % span

*Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm.

**Transmitter URL limit or maximum seal pressure rating, whichever is lower.

***Specification applies to transmitters with 2 seals only. Apply 1.5 times factor to temperature effect for capillary lengths greater than 10 feet.

Image 7
Contents Introduction Guide34-ST-03-64 Description of Diaphragm SealsStainless Steel Nipples are available Description FeaturesSpecifications Operating Conditions All Models Parameter Description Parameter Bar Minimum Span Psig Turndown Ratio Upper Range Limit Psig±0.10 + Or ±0.10 + Performance Under Rated Conditions General for all Models Physical and Approval Bodies 34-ST-03-64 Parameter Description 34-ST-03-64 Supply voltage/loop resistance chart Transmitter at datum Transmitter above datumTransmitter below datum Density, direct acting instrument configuration DP/I Remote Seal With HorizontalPipe Mount LGP/I Remote SealWith Vertical Pipe With Vertical Pipe MountAP/I Remote Seal with Vertical Pipe Mount LGP/I Remote SealOptions Instructions Table II Seals Table II Seals Two 1/2 with plastic plugs Ansi Class 150/300/600 GFA Two 1/4 with plastic plugs PF0 QG0 Wetted Material Table II SealsMD0 NE0Transmitter Mounting Brackets Options Table III Options Warranty OptionsCont’d See in Specification 21a Flush Flanged Seal Dimensions and DrawingsDimensions and Drawings, Dimensions and Drawings, Dimensions and Drawings, Dimensions and Drawings, This page Intentionally Blank