Honeywell STR12D warranty Table II Seals

Page 22

34-ST-03-64 Page 22

 

 

 

 

 

 

 

STR14A

 

 

 

STR12D & 13D

 

 

 

 

14G & 17G

 

 

 

 

 

 

 

TABLE II - SEALS (continued)

 

Selection

 

 

 

 

 

 

 

 

 

 

 

Flush Flanged

Flushing

None

_ _ _ _ _ _ _ _ _ _ _ 0

 

Connections

One 1/4" with plastic plug

_ _ _ _ _ _ _ _ _ _ _ H

6

6

6

 

Seal

and Plugs****

One 1/4" with metal plug

_ _ _ _ _ _ _ _ _ _ _ J

6

6

6

 

 

 

 

(Metal plug material

Two 1/4" with plastic plugs

_ _ _ _ _ _ _ _ _ _ _ M

6

6

6

 

 

will be the same as

Two 1/4" with metal plugs

_ _ _ _ _ _ _ _ _ _ _ N

6

6

6

 

 

Cal. ring material if

One 1/2" with plastic plug

_ _ _ _ _ _ _ _ _ _ _ P

6

6

6

 

 

metal plug is chosen -

One 1/2" with metal plug

_ _ _ _ _ _ _ _ _ _ _ Q

6

6

6

 

 

SS Plug for CS Lower)

Two 1/2" with plastic plugs

_ _ _ _ _ _ _ _ _ _ _ R

6

6

6

 

 

 

Two 1/2" with metal plugs

_ _ _ _ _ _ _ _ _ _ _ S

6

6

6

 

Table II continued below

*Standard facing 125-250 AARH RF (raised face) serrated surface finish. ** Limited vacuum availability.

*** Minimum static pressure requirement. No vacuum allowed. See Specifications Figure 15.

**** Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation a Tantalum Upper insert has Tantalum wetted parts and 316 SS or CS non-wetted parts

Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.

 

 

 

 

 

STR12D & 13D

 

STR14A

 

 

 

 

 

 

 

 

14G & 17G

TABLE II - SEALS (continued)

 

 

Selection

 

 

 

 

 

Diaphragm

Flange

Flange

Const. - See

Construction - See Spec.

 

 

 

 

 

Pressure

Spec. Figure 34-

 

 

 

 

 

Diameter

Size

Figure 34-ST-03-64

 

 

 

 

 

Rating *

ST-03-64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1"

ANSI 150

22

_ _ _ BCA _ _ _ _ _ _

t

4

 

 

 

ANSI 300

22

_ _ _ BCC _ _ _ _ _ _

t

4

 

 

 

 

 

 

 

1-1/2"

ANSI 150

22

_ _ _ BGA _ _ _ _ _ _

t

4

 

 

 

ANSI 300

22

_ _ _ BGC _ _ _ _ _ _

t

4

 

 

2.4"

 

 

 

2"

ANSI 150

22

_ _ _ BDA _ _ _ _ _ _

t

4

 

 

 

 

 

 

ANSI 300

22

_ _ _ BDC _ _ _ _ _ _

t

4

 

 

 

 

 

 

 

3"

ANSI 150

22

_ _ _ BFA _ _ _ _ _ _

t

4

 

 

 

ANSI 300

22

_ _ _ BFC _ _ _ _ _ _

t

4

 

 

 

 

 

 

 

1/2"

ANSI 150

23

_ _ _ CAA _ _ _ _ _ _

 

 

 

1"

ANSI 150

23

_ _ _ CCA _ _ _ _ _ _

 

 

 

ANSI 300

23

_ _ _ CCC _ _ _ _ _ _

 

Flush Flanged

2.9"

 

 

1-1/2"

ANSI 150

22

_ _ _ CGA _ _ _ _ _ _

 

Seal with Lower

 

ANSI 300

22

_ _ _ CGC _ _ _ _ _ _

 

 

 

 

 

 

2"

ANSI 150

22

_ _ _ CDA _ _ _ _ _ _

 

 

 

ANSI 300

22

_ _ _ CDC _ _ _ _ _ _

 

 

 

 

 

 

 

1/2"

ANSI 150

22

_ _ _ DAA _ _ _ _ _ _

 

 

 

1"

ANSI 150

23

_ _ _ DCA _ _ _ _ _ _

 

 

 

ANSI 300

23

_ _ _ DCC _ _ _ _ _ _

 

 

 

 

 

 

4.1"

1-1/2"

ANSI 150

23

_ _ _ DGA _ _ _ _ _ _

 

 

ANSI 300

23

_ _ _ DGC _ _ _ _ _ _

 

 

 

 

 

 

2"

ANSI 150

23

_ _ _ DDA _ _ _ _ _ _

 

 

 

ANSI 300

22

_ _ _ DDC _ _ _ _ _ _

 

 

 

 

 

 

 

3"

ANSI 150

22

_ _ _ DFA _ _ _ _ _ _

 

 

 

ANSI 300

22

_ _ _ DFC _ _ _ _ _ _

 

 

 

 

 

Table II continued next page

*Standard facing 125-250 AARH RF (raised face) serrated finish.

**Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.

Image 22
Contents Guide IntroductionDescription of Diaphragm Seals 34-ST-03-64Stainless Steel Nipples are available Features DescriptionSpecifications Operating Conditions All Models Parameter Description Parameter Upper Range Limit Psig Bar Minimum Span Psig Turndown Ratio±0.10 + Or ±0.10 + Performance Under Rated Conditions General for all Models Physical and Approval Bodies 34-ST-03-64 Parameter Description 34-ST-03-64 Supply voltage/loop resistance chart Transmitter at datum Transmitter above datumTransmitter below datum Density, direct acting instrument configuration LGP/I Remote Seal With HorizontalPipe Mount DP/I Remote SealLGP/I Remote Seal With Vertical Pipe MountAP/I Remote Seal with Vertical Pipe Mount With Vertical PipeOptions Instructions Table II Seals Table II Seals Two 1/2 with plastic plugs Ansi Class 150/300/600 GFA Two 1/4 with plastic plugs NE0 Table II SealsMD0 PF0 QG0 Wetted MaterialTransmitter Mounting Brackets Options Warranty Options Table III OptionsCont’d See in Specification Dimensions and Drawings 21a Flush Flanged SealDimensions and Drawings, Dimensions and Drawings, Dimensions and Drawings, Dimensions and Drawings, This page Intentionally Blank