34-ST-03-64 Page 22
|
|
|
|
|
|
| STR14A | ||
|
|
| STR12D & 13D |
|
|
|
| 14G & 17G | |
|
|
|
|
|
|
| |||
TABLE II - SEALS (continued) |
| Selection |
|
|
|
|
| ||
|
|
|
|
|
| ||||
Flush Flanged | Flushing | None | _ _ _ _ _ _ _ _ _ _ _ 0 | ● | ● | ● |
| ||
Connections | One 1/4" with plastic plug | _ _ _ _ _ _ _ _ _ _ _ H | 6 | 6 | 6 |
| |||
Seal | and Plugs**** | One 1/4" with metal plug | _ _ _ _ _ _ _ _ _ _ _ J | 6 | 6 | 6 |
| ||
|
| ||||||||
| (Metal plug material | Two 1/4" with plastic plugs | _ _ _ _ _ _ _ _ _ _ _ M | 6 | 6 | 6 |
| ||
| will be the same as | Two 1/4" with metal plugs | _ _ _ _ _ _ _ _ _ _ _ N | 6 | 6 | 6 |
| ||
| Cal. ring material if | One 1/2" with plastic plug | _ _ _ _ _ _ _ _ _ _ _ P | 6 | 6 | 6 |
| ||
| metal plug is chosen - | One 1/2" with metal plug | _ _ _ _ _ _ _ _ _ _ _ Q | 6 | 6 | 6 |
| ||
| SS Plug for CS Lower) | Two 1/2" with plastic plugs | _ _ _ _ _ _ _ _ _ _ _ R | 6 | 6 | 6 |
| ||
|
| Two 1/2" with metal plugs | _ _ _ _ _ _ _ _ _ _ _ S | 6 | 6 | 6 |
|
Table II continued below
*Standard facing
*** Minimum static pressure requirement. No vacuum allowed. See Specifications Figure 15.
**** Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation a Tantalum Upper insert has Tantalum wetted parts and 316 SS or CS
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
|
|
|
|
| STR12D & 13D |
| STR14A | ||
|
|
|
|
|
|
|
| 14G & 17G | |
TABLE II - SEALS (continued) |
|
| Selection |
|
|
|
| ||
| Diaphragm | Flange | Flange | Const. - See | Construction - See Spec. |
|
|
|
|
| Pressure | Spec. Figure 34- |
|
|
|
| |||
| Diameter | Size | Figure |
|
|
|
| ||
| Rating * |
|
|
|
| ||||
|
|
|
|
|
|
|
| ||
|
| 1" | ANSI 150 | 22 | _ _ _ BCA _ _ _ _ _ _ | t | 4 | ● |
|
|
| ANSI 300 | 22 | _ _ _ BCC _ _ _ _ _ _ | t | 4 | ● |
| |
|
|
|
| ||||||
|
| ANSI 150 | 22 | _ _ _ BGA _ _ _ _ _ _ | t | 4 | ● |
| |
|
| ANSI 300 | 22 | _ _ _ BGC _ _ _ _ _ _ | t | 4 | ● |
| |
| 2.4" |
|
| ||||||
| 2" | ANSI 150 | 22 | _ _ _ BDA _ _ _ _ _ _ | t | 4 | ● |
| |
|
|
| |||||||
|
| ANSI 300 | 22 | _ _ _ BDC _ _ _ _ _ _ | t | 4 | ● |
| |
|
|
|
| ||||||
|
| 3" | ANSI 150 | 22 | _ _ _ BFA _ _ _ _ _ _ | t | 4 | ● |
|
|
| ANSI 300 | 22 | _ _ _ BFC _ _ _ _ _ _ | t | 4 | ● |
| |
|
|
|
| ||||||
|
| 1/2" | ANSI 150 | 23 | _ _ _ CAA _ _ _ _ _ _ | ● | ● | ● |
|
|
| 1" | ANSI 150 | 23 | _ _ _ CCA _ _ _ _ _ _ | ● | ● | ● |
|
|
| ANSI 300 | 23 | _ _ _ CCC _ _ _ _ _ _ | ● | ● | ● |
| |
Flush Flanged | 2.9" |
|
| ||||||
ANSI 150 | 22 | _ _ _ CGA _ _ _ _ _ _ | ● | ● | ● |
| |||
Seal with Lower |
| ANSI 300 | 22 | _ _ _ CGC _ _ _ _ _ _ | ● | ● | ● |
| |
|
|
| |||||||
|
| 2" | ANSI 150 | 22 | _ _ _ CDA _ _ _ _ _ _ | ● | ● | ● |
|
|
| ANSI 300 | 22 | _ _ _ CDC _ _ _ _ _ _ | ● | ● | ● |
| |
|
|
|
| ||||||
|
| 1/2" | ANSI 150 | 22 | _ _ _ DAA _ _ _ _ _ _ | ● | ● | ● |
|
|
| 1" | ANSI 150 | 23 | _ _ _ DCA _ _ _ _ _ _ | ● | ● | ● |
|
|
| ANSI 300 | 23 | _ _ _ DCC _ _ _ _ _ _ | ● | ● | ● |
| |
|
|
|
| ||||||
| 4.1" | ANSI 150 | 23 | _ _ _ DGA _ _ _ _ _ _ | ● | ● | ● |
| |
| ANSI 300 | 23 | _ _ _ DGC _ _ _ _ _ _ | ● | ● | ● |
| ||
|
|
| |||||||
|
| 2" | ANSI 150 | 23 | _ _ _ DDA _ _ _ _ _ _ | ● | ● | ● |
|
|
| ANSI 300 | 22 | _ _ _ DDC _ _ _ _ _ _ | ● | ● | ● |
| |
|
|
|
| ||||||
|
| 3" | ANSI 150 | 22 | _ _ _ DFA _ _ _ _ _ _ | ● | ● | ● |
|
|
| ANSI 300 | 22 | _ _ _ DFC _ _ _ _ _ _ | ● | ● | ● |
| |
|
|
|
|
Table II continued next page
*Standard facing
**Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.