Honeywell STR12D warranty Upper Range Limit Psig, Bar Minimum Span Psig Turndown Ratio

Page 8

34-ST-03-64 Page 8

Performance Under Rated Conditions * - Model STR14G (0-5 to 0-500 psig)

 

Parameter

 

 

 

 

 

 

 

Description

 

Upper Range Limit **

psig

500

 

 

 

 

 

 

 

 

 

 

 

bar

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Span

psig

5

 

 

 

 

 

 

 

 

 

 

 

bar

0.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turndown Ratio

 

 

100 to 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zero Elevation and Suppression

 

No limit except minimum span from absolute zero to 100% of URL. Specifications valid

 

 

 

 

over this range.

 

 

 

 

 

 

 

 

 

 

Accuracy (Reference – Includes

 

In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is

 

combined effects of linearity,

 

 

greater.

 

 

 

 

 

 

hysteresis, and repeatability)

 

 

For URV below reference point (20 psi), accuracy equals:

 

 

 

 

 

Accuracy includes residual error

 

 

 

20 psi

 

1.4 bar

 

after averaging successive

 

 

±0.05 + 0.05 (

 

 

) or

±0.05 + 0.05 (

 

 

) in % of span

 

 

 

span psi

span bar

 

readings.

 

 

In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is

 

For FOUNDATION Fieldbus use

 

 

 

greater.

 

 

 

 

 

 

Digital Mode specifications. For

 

 

 

 

 

 

 

 

For URV below reference point (20 psi), accuracy equals:

 

HART use Analog Mode

 

 

 

specifications.

 

 

 

 

20 psi

 

 

1.4 bar

 

 

 

 

±0.025 + 0.05 (

 

) or

±0.025 + 0.05 (

 

) in % of span

 

 

 

 

span psi

span bar

*Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm.

**Transmitter URL limit or maximum seal pressure rating, whichever is lower.

Image 8
Contents Guide IntroductionDescription of Diaphragm Seals 34-ST-03-64Stainless Steel Nipples are available Features DescriptionSpecifications Operating Conditions All Models Parameter Description Parameter Upper Range Limit Psig Bar Minimum Span Psig Turndown Ratio±0.10 + Or ±0.10 + Performance Under Rated Conditions General for all Models Physical and Approval Bodies 34-ST-03-64 Parameter Description 34-ST-03-64 Supply voltage/loop resistance chart Transmitter below datum Transmitter above datumTransmitter at datum Density, direct acting instrument configuration With Horizontal Pipe MountLGP/I Remote Seal DP/I Remote SealWith Vertical Pipe Mount AP/I Remote Seal with Vertical Pipe MountLGP/I Remote Seal With Vertical PipeOptions Instructions Table II Seals Table II Seals Two 1/2 with plastic plugs Ansi Class 150/300/600 GFA Two 1/4 with plastic plugs Table II Seals MD0NE0 PF0 QG0 Wetted MaterialTransmitter Mounting Brackets Options Warranty Options Table III OptionsCont’d See in Specification Dimensions and Drawings 21a Flush Flanged SealDimensions and Drawings, Dimensions and Drawings, Dimensions and Drawings, Dimensions and Drawings, This page Intentionally Blank