SPECIFICATIONS
Name | |||
Model |
| ||
External dimensions | W2010 x D770 x H1070 (mm) |
| W2570 x D770 x H1070 (mm) |
Internal dimensions | W1280 x D500x H762 (mm) |
| W1840 x D500x H762 (mm) |
Effective capacity | 487 L |
| 701 L |
Exterior | Baked on acrylic finish on galvanized steel | ||
Interior | Stainless steel |
| |
Door | Baked on acrylic finish on galvanized steel | ||
Insulation | Rigid polyurethane | ||
Compressor | Hermetic type |
| |
Motor for compressor | High stage side; 750 W |
| High stage side; 1100 W |
| Low stage side; 750 W |
| Low stage side; 1100 W |
Condenser | High stage side; fin and tube type, Low stage side; shell and tube type | ||
Evaporator | Tube on sheet type | ||
Refrigerant | High stage side; | ||
Power source | AC 200 V, 60 Hz | ||
Temperature controller | Microprocessor control system, Setting range; | ||
Temperature display | Digital display (+50 to | ||
Sensor | Pt 100Ω |
| |
Alarm | |||
Battery | For power failure alarm; 6VDC, 270mAh | ||
Voltage booster | Electrical; 208/230 V, 1 HP, 60 Hz | ||
| Minimum operating voltage; 193 V at | ||
Accessories | 1 set of key, 2 rubber caps, 1 scraper | ||
Weight | 319 kg |
| 380 kg |
Option | Aluminum container; | ||
| Temperature recorder; | ||
Note: Design or specifications will be subject to change without notice. |
|
The battery for power failure alarm is an article for consumption. It is recommended that the battery will be replaced about every 3 years. Contact Sanyo sales agency at the time of replacement of the battery for recycling.
PERFORMANCE
Model |
| ||
Cooling performance | Center part of freezing room; | ||
Temperature Control range |
| ||
Power source |
| AC 200V, 60Hz | |
Rated power consumption | 1100 W |
| 1240 W |
Noise level | 61 dB [A] (background noise; 20 dB) | ||
Maximum pressure | 1.9 MPa |
| 2.1 MPa |
Note : The unit with CE mark complies with EC directives 89/336/EEC, 93/68/EEC and 73/23/EEC
27