Testing Procedures
!WARNING
Disconnect power before performing the following procedures unless testing requires it.
4.Measure resistance of the terminals on the high voltage transformer with meter on R x 1 scale.
Reading should be indicated as follows: Primary winding ......less than 1.0 ohms Filament winding ....less than 1.0 ohms Secondary winding . approximately 50 to 120 ohms
5.Measure resistance of the terminals on the high voltage transformer with meter on high scale.
Reading should be indicated as follows: Primary winding to ground ....... Infinite ohms Filament winding to ground ..... Infinite ohms
High Voltage Capacitor
1.Disconnect power to oven and remove control panel, (see “Control Panel” section in Disassembly Procedure).
2.Discharge high voltage capacitor, (see "High Voltage Capacitor" section in Disassembly Procedure).
3.Disconnect wire leads to high voltage capacitor.
4.Measure resistance of capacitor from terminal to terminal.
•Normal
•Abnormal
5.Measure resistance of capacitor from terminal to case.
•Normal
•Abnormal
High Voltage Diode
1.Disconnect power to oven and remove control panel, (see “Control Panel” section in Disassembly Procedure).
2.Discharge high voltage capacitor, (see "High Voltage Capacitor" section in Disassembly Procedure).
3.Disconnect wire leads to high voltage diode.
4.Measure resistance of diode in forward bias.
•Normal
•Abnormal
5.Measure resistance of diode in reverse bias.
•Normal
•Abnormal
Humidity Sensor
1.Disconnect power to oven and remove control panel, (see “Control Panel” section in Disassembly Procedure).
2.Discharge high voltage capacitor, (see "High Voltage Capacitor" section in Disassembly Procedure).
3.Disconnect wire terminal plug from control board (CN5).
4.Measure the following terminals with meter on R x 1000 scale.
Normal indication:
Terminal 1 to terminal 2 ......... 4.5K to 6.2K ohms Terminal 2 to terminal 3 ........ 2.0K to 3.5K ohms Terminal 1 to terminal 3 ........ 2.0K to 3.5K ohms
Abnormal indication: Infinite or several ohms
Relay
1.Disconnect power to oven and remove control panel, (see “Control Panel” section in Disassembly Procedure).
2.Discharge high voltage capacitor, (see "High Voltage Capacitor" section in Disassembly Procedure).
3.Disconnect wire terminal plug from control board (ACO18*, RY2) (ACO15*, RY7), and operate the unit.
Relay 2 |
Power Level | Cycles On for: | Cycles Off for: |
|
|
|
1 | 4 seconds | 18 seconds |
2 | 6 seconds | 16 seconds |
3 | 8 seconds | 14 seconds |
4 | 10 seconds | 12 seconds |
5 | 12 seconds | 10 seconds |
6 | 14 seconds | 8 seconds |
7 | 16 seconds | 6 seconds |
8 | 18 seconds | 4 seconds |
9 | 20 seconds | 2 seconds |
10 | 22 seconds | 0 seconds |
|
|
|
Control Key Panel
1.Disconnect power to oven and remove control panel, (see “Control Panel” section in Disassembly Procedure).
2.Discharge high voltage capacitor, (see "High Voltage Capacitor" section in Disassembly Procedure).